4-24
Sun Fire X4140 Server Service Manual • September 2010
4.6.2
Installing the Motherboard Assembly
Caution –
This procedure requires that you handle components that are sensitive to
static discharge. Static discharges can cause the component failures. To avoid
damage, ensure that you follow antistatic practices as described in
Section 2.7,
“Performing Electrostatic Discharge and Antistatic Prevention Measures” on
page 2-9
.
1. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
2. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
3. Place the motherboard into the chassis (
FIGURE 4-13
).
Position the motherboard carefully.
FIGURE 4-13
Installing the Motherboard Assembly