3-6
Sun Fire X4140 Server Service Manual • September 2010
2. Determine if the drive can be hot-plugged, or cold-plugged.
The following conditions might prevent you from hot-plugging a drive. You must
power off the server, if the drive:
■
Contains the operating system, and the operating system is not mirrored on
another drive.
■
Cannot be logically isolated from the online operations of the server.
3. Do one of the following:
■
To hot-plug a drive:
i. Unconfigure the drive, as required. You must take the drive offline (to
prevent any applications from accessing it, and to remove the logical
software links to it) before you can safely remove it.
See one of the following HBA documents:
For Sun StorageTek:
Sun StorageTek RAID Manager Software User's Guide
For LSI MegaRAID Storage Manager (MSM):
x64 Server Utilities Reference
Manual
i. Wait until the blue
OK to Remove
LED becomes lit (
FIGURE 3-2
) before you
physically uninstall the drive from the chassis.
The blue LED indicates that the drive is unconfigured and can be removed.
■
To cold-plug a drive:
You must power off the server before you can safely remove the drive. Do one
of the procedures described in
Section 2.4, “Powering Off the Server” on
page 2-4
.
4. On the drive you plan to remove, push the drive release button to open the latch
([1]
FIGURE 3-3
).
5. Grasp the latch [2] and pull the drive out of the drive slot [3].
Caution –
The latch is not an ejector. Do not bend it too far to the right. Doing so can
damage the latch.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...