Appendix B
BIOS Power-On Self-Test (POST) Codes
B-3
7. Select the IP Address menu item.
The SP’s IP address appears
8. Start a web browser and type the SP’s IP address in the browser’s address bar.
9. Type a user name and password as follows:
User name:
root
Password:
changeme
10. The ILOM SP web GUI screen appears.
11. Click the Remote Control tab.
12. Click the Redirection tab.
13. Click on the Start Redirection button.
The javaRConsole window appears and prompts you for your user name and
password again.
14. When you are prompted, type a user name and password with administrator
privileges.
The current POST screen appears.
B.4
Changing POST Options
These instructions are optional, but you can use them to change the operations that
the server performs during POST testing.
To Change POST Options
1. Initialize the BIOS Setup Utility by pressing the F2 key while the system is
performing the power-on self-test (POST).
The BIOS Main Menu screen appears.
2. Select the Boot menu.
The Boot Settings screen appears.
3. Select Boot Settings Configuration.
The Boot Settings Configuration screen appears.
4. On the Boot Settings Configuration screen, there are several options that you
can enable or disable:
■
Hit 'F2' Message Display:
Displays “Press F2 to run Setup” in POST. This
option is enabled by default.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...