4-36
Sun Fire X4140 Server Service Manual • September 2010
13. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
14. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.
CMOS NVRAM is cleared.
4.10
Recovering From Corrupt Service
Processor Software
If the SP (service processor) software becomes corrupted, you can reinstall the default
SP software image from the Tools and Drivers CD.
You need the following:
■
Tools and Drivers CD.
■
Bootable USB flash device.
4.10.1
Reinstalling The Default SP Software Image From
The Tools And Drivers CD
This emergency flash recovery procedure returns the SP to a default configuration.
The ILOM SPBIOS <
file-name
>
.pkg
file format (for example
ilom.X4150-2.0.2.6.pkg
) cannot be used for emergency recovery. Use the
<
file-name
>
.bin
recovery image instead.
1. Copy the following SP files from the Tools and Drivers CD, located in the
recovery
directory, to a USB bootable flash device.
■
SOCFLASH.EXE
■
DOS4GW
■
BMC Binary
(the SP Binary file)
2. Insert the bootable flash drive into the USB port.
a. Press F8 to get a list of the boot devices.
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...