Chapter 5
Servicing Infrastructure Boards and Components
5-11
7. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
8. Install the server into the rack.
See
Section 6.2, “Reinstalling the Server in the Rack” on page 6-3
.
9. Install the drives.
Note –
Ensure you are installing the drives in the correct drive bays.
See
Section 3.2.5, “Installing a Hard Drive or SSD” on page 3-7
.
10. Install the DVD/USB module.
See
Section 5.1.2, “Installing the DVD/USB Module” on page 5-3
.
11. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
12. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.
5.4
Servicing the Drives Backplane
Note –
FRU
: This field-replaceable unit should be replaced only by qualified service
technicians. Contact your Sun Service representative for assistance.
5.4.1
Removing the Drives Backplane
1. Remove the drives cage.
See
Section 5.3.1, “Removing the Drives Cage” on page 5-7
.
2. Remove the two No. 2 Phillips screws securing the backplane to the drives cage
(
FIGURE 5-7
).
Содержание Sun Fire X4140
Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 35: ...Chapter 2 Preparing to Service the System 2 11...
Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...