Sun Fire™ X4140 Server

Service Manual

Part No. 820-2401-14
September 2010, Revision A

Содержание Sun Fire X4140

Страница 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...

Страница 2: ...r CE PRODUIT CONTIENT DES INFORMATIONS CONFIDENTIELLES ET DES SECRETS COMMERCIAUX DE SUN MICROSYSTEMS INC SON UTILISATION SA DIVULGATION ET SA REPRODUCTION SONT INTERDITES SANS L AUTORISATION EXPRESSE...

Страница 3: ...ront Panel Features 1 8 1 4 Sun Fire X4140 Server Rear Panel Features 1 9 1 5 Illustrated Parts Breakdown 1 10 2 Preparing to Service the System 2 1 2 1 Safety Information 2 1 2 2 Required Tools 2 2 2...

Страница 4: ...1 1 Hot Pluggable Devices 3 1 3 1 2 Hot Swappable Devices 3 2 3 2 Servicing Drives 3 2 3 2 1 Sun Fire X4140 Server Drive Guidelines 3 2 3 2 2 Sun Fire X4140 Server Solid State Drive Guidelines 3 3 3 2...

Страница 5: ...4 Installing DDR2 DIMMs 4 7 4 1 5 Installing Additional DDR2 DIMMs 4 9 4 2 Servicing the Air Baffle 4 10 4 2 1 Removing the Air Baffle 4 11 4 2 2 Installing the Air Baffle 4 12 4 3 Servicing PCIe Rise...

Страница 6: ...Installing a Processor FRU 4 32 4 8 4 Installing an XOption Processor 4 33 4 9 Resetting Passwords and Clearing CMOS NVRAM 4 35 4 9 1 Overview 4 35 4 9 2 Resetting a BIOS Password From the BIOS Screen...

Страница 7: ...5 6 1 Removing the Power Distribution Board 5 15 5 6 2 Installing the Power Distribution Board 5 16 5 7 Servicing the Paddle Card 5 17 5 7 1 Removing the Paddle Card 5 18 5 7 2 Installing the Paddle C...

Страница 8: ...Memory Testing Works B 2 B 3 Redirecting Console Output B 2 B 4 Changing POST Options B 3 B 5 POST Codes B 4 C BIOS Screens C 1 C 1 Configuring BIOS Settings C 1 C 1 1 Using BIOS Menu Items C 1 C 1 2...

Страница 9: ...hapter Describes Chapter 1 Sun Fire X4140 Server Overview provides an overview of the system including front and rear panel features Contains illustrations showing system components Chapter 2 Preparin...

Страница 10: ...s Documentation Where to find the documentation for the Sun Fire X4140 X4240 and X4440 servers 820 2395 Sun Fire X4140 X4240 and X4440 Server Installation Guide How to install the Sun Fire X4140 X4240...

Страница 11: ...ervers Utilities Reference Manual Contains instructions for using applications and utilities common to many X64 servers 820 1120 TABLE P 3 Sun Fire X4140 Server Online Documents Sun Function URL Descr...

Страница 12: ...urfaces are hot and might cause personal injury if touched Caution Hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions Sun Welcome...

Страница 13: ...on page 1 3 Section 1 3 Sun Fire X4140 Server Front Panel Features on page 1 8 Section 1 4 Sun Fire X4140 Server Rear Panel Features on page 1 9 Section 1 5 Illustrated Parts Breakdown on page 1 10 1...

Страница 14: ...ers Internal drives SAS up to 8 or SATA up to 4 SSDs Up to 8 SFF SAS 73 GB or 146 GB 2 5 inch form factor drives Support for hardware integrated RAID 0 striping and RAID 1 mirroring Optional RAID Leve...

Страница 15: ...Remote graphical access remote KVM over Ethernet Remote storage over Ethernet Operating system Solaris 10 Update 4 Solaris 10 OS with specific Sun Fire X4140 Server software components Supports Red H...

Страница 16: ...e It also supports a top cover interlock kill switch In the Sun Fire X4140 Server the power supplies connect directly to the power distribution board Section 5 6 Servicing the Power Distribution Board...

Страница 17: ...E 1 3 Sun Fire X4140 Server Dimensions Dimension Sun Fire X4140 Server Height 44 mm 1 73 inches Width 425 5 mm 16 75 inches Depth 711 2 mm 28 0 inches Weight Minimum 13 9 kg 30 6 lbs Maximum 18 4 kg 4...

Страница 18: ...er Service Manual September 2010 FIGURE 1 1 Cables for Sun Fire X4140 Server With SATA On board System Controller Figure Legend 1 SATA Drives Data Cable 2 Motherboard to Power Distribution Board Cable...

Страница 19: ...Chapter 1 Sun Fire X4140 Server Overview 1 7 FIGURE 1 2 Cables for Sun Fire X4140 Server With SAS Caution The Drives Data Cable X and O connectors must be placed in the order shown...

Страница 20: ...panel features on the Sun Fire X4140 Server FIGURE 1 3 Front Panel Features Figure Legend 1 Locator LED Locator button white 5 Drive map 2 Service Action Required LED amber 6 Power Supply Service Requ...

Страница 21: ...lation Guide For a detailed description of PCIe slots see Section 4 4 1 Sun Fire X4140 Server PCIe Card Guidelines on page 4 16 FIGURE 1 4 Rear Panel Features Figure Legend 1 PSU 0 7 Serial Management...

Страница 22: ...ower distribution and fan module components Use these illustrations and the accompanying tables to identify parts in your system FIGURE 1 5 Sun Fire X4140 Server I O Components Figure Legend 1 Top Cov...

Страница 23: ...ire X4140 Server Overview 1 11 FIGURE 1 6 Power Distribution and Fan Module Components Figure Legend 1 Paddle Card 4 Power Supplies 2 Power Distribution Board Bus Bar Assembly 5 Fan Modules 3 Air Baff...

Страница 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...

Страница 25: ...er to the Maintenance Position on page 2 5 Section 2 6 Removing a Server From the Rack on page 2 7 Section 2 7 Performing Electrostatic Discharge and Antistatic Prevention Measures on page 2 9 Section...

Страница 26: ...ent s electrical rating label Follow the electrostatic discharge safety practices as described in this chapter 2 2 Required Tools The Sun Fire X4140 Server can be serviced with the following tools Ant...

Страница 27: ...ct to press and release the Power button on the front panel Pressing the power button causes Advanced Configuration and Power Interface ACPI enabled operating systems to perform an orderly shutdown of...

Страница 28: ...data is saved and the server is ready for restart Refer to the Solaris operating system documentation for additional information 1 Log in as a superuser or equivalent Depending on the type of problem...

Страница 29: ...prompt to locate the system that requires maintenance After you have located the server press the Locator LED Locator button to turn it off 2 Verify that no cables will be damaged or will interfere w...

Страница 30: ...ll the server forward until the slide rails latch 2 6 Removing a Server From the Rack The server must be removed from the rack to service the following components Motherboard Power distribution board...

Страница 31: ...tion See Section 2 5 Extending the Server to the Maintenance Position on page 2 5 4 Press the metal lever that is located on the inner side of the rail to disconnect the cable management arm CMA from...

Страница 32: ...ase Tabs and Slide Assembly 6 Set the server on a sturdy work surface 2 7 Performing Electrostatic Discharge and Antistatic Prevention Measures 2 7 1 Electrostatic Discharge Safety Measures Electrosta...

Страница 33: ...cal potentials between you and the server Note An antistatic wrist strap is not included in the accessory kit for the Sun Fire X4140 Server However antistatic wrist straps are still included with opti...

Страница 34: ...Pull the two release tabs back to release the door Rotate the fan door to the open position and hold it there 2 Press the top cover release button and slide the top cover toward the rear of the serve...

Страница 35: ...Chapter 2 Preparing to Service the System 2 11...

Страница 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...

Страница 37: ...es on page 3 14 CRU 3 1 Devices That Are Hot Pluggable or Hot Swappable Some of the procedures in this section are for customer replaceable units CRUs and some are for field replaceable units FRUs as...

Страница 38: ...ction 3 4 Servicing Power Supplies on page 3 14 Note The chassis mounted drives can be hot swappable depending on how they are configured See Section 3 2 Servicing Drives on page 3 2 3 2 Servicing Dri...

Страница 39: ...nder the following conditions Sun Fire X4140 with on board controller No SSDs can be installed Sun Fire X4140 with HBA One to 4 SSDs can be installed The remaining slots can be filled with hard drives...

Страница 40: ...re that the firmware on the newly installed SSD is the same as the firmware that is installed on the other SSDs in the RAID volume Miminum required firmware BIOS ILOM Firmware BIOS 0ABMN064 ILOM 3 0 3...

Страница 41: ...safely remove it To remove a drive from a Sun Fire X4140 Server 1 Identify the drive you wish to remove The amber Service Required LED might be lit For specific drive locations see Section 3 2 1 Sun F...

Страница 42: ...ve it See one of the following HBA documents For Sun StorageTek Sun StorageTek RAID Manager Software User s Guide For LSI MegaRAID Storage Manager MSM x64 Server Utilities Reference Manual i Wait unti...

Страница 43: ...detected the missing failed drive To install a drive into a Sun Fire X4140 Server 1 If necessary remove the drive fillers from the chassis The Sun Fire X4140 Server might have as many as eight drive f...

Страница 44: ...Tek RAID Manager Software User s Guide For LSI MegaRAID Storage Manager MSM x64 Server Utilities Reference Manual If you have cold plugged the drive Restore power to the server Do the procedure descri...

Страница 45: ...ure on page 3 11 Section 3 3 4 Removing a Fan Module on page 3 11 Section 3 3 5 Installing a Fan Module on page 3 12 Note CRU This customer replaceable unit can be replaced by anyone 3 3 1 About Sun F...

Страница 46: ...module LEDs and their functions FIGURE 3 6 shows fan tray module LED locations FIGURE 3 6 Fan Module Status LEDs TABLE 3 4 Fan Module Status LEDs LED Color Lights when Power OK Green The system is po...

Страница 47: ...ntifying and interpreting system LEDs 3 3 4 Removing a Fan Module Caution Hazardous moving parts Unless the power to the server is completely shut down the only service permitted in the fan compartmen...

Страница 48: ...service any other components in the fan compartment unless the system is shut down and the power cords are removed FIGURE 3 7 Removing a Fan Module 3 3 5 Installing a Fan Module 1 With the top cover...

Страница 49: ...at Fan OK LED is lit and that the Fan Fault LED on the replaced fan module is not lit 4 Close the top cover door 5 Verify that the Top Fan LED Service Required LEDs and the Locator LED Locator button...

Страница 50: ...vered Section 3 4 1 Detecting Power Supply Failure on page 3 14 Section 3 4 2 Power Supply LED Reference on page 3 14 Section 3 4 3 Removing a Power Supply on page 3 15 Section 3 4 4 Installing a Powe...

Страница 51: ...a power supply indicates that a failure was detected 2 Gain access to the rear of the server where the faulty power supply is located Figure Legend Legend LED Symbol Color Lights when 1 OK to Remove B...

Страница 52: ...server rack FIGURE 3 10 Releasing the Cable Management Arm a Press and hold the tab b Rotate the cable management arm out of the way so that you can access the power supply 4 Disconnect the power cor...

Страница 53: ...e Devices 3 17 FIGURE 3 11 Power Supply Release Handle 3 4 4 Installing a Power Supply 1 Align the replacement power supply with the empty power supply chassis bay 2 Slide the power supply into the ba...

Страница 54: ...RE 3 10 5 Verify that the following LEDs are not lit Failure LED on the replaced power supply Service Required LED Front Service Required LED Rear Service Required LED Note See Section 1 3 Sun Fire X4...

Страница 55: ...rs on page 4 13 CRU Section 4 4 Servicing PCIe Cards on page 4 15 CRU Section 4 5 Servicing the Battery on page 4 19 CRU Section 4 6 Servicing the Motherboard Assembly on page 4 21 FRU Section 4 7 Ser...

Страница 56: ...res that you handle components that are sensitive to static discharge This sensitivity can cause the component to fail To avoid damage ensure that you follow antistatic practices as described in Secti...

Страница 57: ...supports the following configurations such as 2 DDR2 DIMMs 4 DDR2 DIMMs 6 DDR2 DIMMs 8 DDR2 DIMMs 16 DDR2 DIMMs fully populated configuration Any even number of DIMMs is allowed The DIMMs must be pop...

Страница 58: ...Ms have 18 DRAMs while dual rank DIMMs have 36 DRAMs Refer to the service label on the cover for DDR2 DIMM placement information Refer to the Sun Fire X4140 X4240 and X4440 Servers Diagnostics Guide f...

Страница 59: ...92 Commands cd show Note DDR2 DIMM names in Integrated LOM messages are displayed with the full name such as SYS MB DIMM_D0 4 1 2 2 Single Processor Configuration DDR2 DIMM Placement If a one processo...

Страница 60: ...intenance position See Section 2 5 Extending the Server to the Maintenance Position on page 2 5 d Attach an antistatic wrist strap See Section 2 7 Performing Electrostatic Discharge and Antistatic Pre...

Страница 61: ...ll power is removed from the server before removing or installing DDR2 DIMMs or damage to the DDR2 DIMMs might occur You must disconnect all power cables from the system before performing this procedu...

Страница 62: ...n of the DDR2 DIMM is as shown in FIGURE 4 4 If the orientation is reversed damage to the DDR2 DIMM might occur 5 Repeat Step 2 through Step 4 until all replacement DDR2 DIMMs are installed 6 Install...

Страница 63: ...s removed from the server before installing DDR2 DIMMs or damage to the DDR2 DIMMs might occur You must disconnect all power cables from the system before performing this procedure 1 Unpackage the rep...

Страница 64: ...rack See Section 6 3 Returning the Server to the Normal Rack Position on page 6 4 c Reconnect the power cord or cords to the power supply or supplies Verify that the AC Present LED is lit See Section...

Страница 65: ...on page 2 4 c Slide the server out of the rack See Section 2 5 Extending the Server to the Maintenance Position on page 2 5 d Attach an antistatic wrist strap See Section 2 7 Performing Electrostatic...

Страница 66: ...and fully seated in the chassis 2 Return the server to operation a Install the top cover See Section 6 1 Installing the Top Cover on page 6 2 b Slide the server into the rack See Section 6 3 Returnin...

Страница 67: ...can cause the component to fail To avoid damage ensure that you follow antistatic practices as described in Section 2 7 Performing Electrostatic Discharge and Antistatic Prevention Measures on page 2...

Страница 68: ...emove the rear panel crossbar a Loosen the captive Phillips screw on each end of the rear panel crossbar b Lift the crossbar up and back to remove it from the chassis 6 Lift the riser up to remove it...

Страница 69: ...ews 5 Slide the server into the rack See Section 6 3 Returning the Server to the Normal Rack Position on page 6 4 6 Connect any data cables you removed to service the PCIe cards 7 Reconnect the power...

Страница 70: ...1 Riser Cards The PCI expansion system is configured using two types of riser cards Riser type 1 is used in the Riser 0 and Riser 1 positions and Riser type 2 is used in the slot 2 position as shown i...

Страница 71: ...s on page 1 9 for more information about PCIe slots and their locations 2 If necessary make a note of where the PCIe cards are installed 3 Unplug all data cables from the card Note the location of all...

Страница 72: ...filler panels are located in the motherboard rear panel 7 Insert the PCIe card into the correct slot on the riser board FIGURE 4 10 8 Replace the riser board a Slide the riser back until it seats in i...

Страница 73: ...hen the server is powered off and a time server is unavailable If the server fails to maintain the proper time when powered off and not connected to a network replace the battery You need a small No 1...

Страница 74: ...ser on page 4 13 See Section 4 4 1 Sun Fire X4140 Server PCIe Card Guidelines on page 4 16 2 Using a small No 1 flat blade screwdriver press the latch and remove the battery from the motherboard 4 5 2...

Страница 75: ...Note FRU This field replaceable unit should be replaced only by qualified service technicians Contact your Sun Service representative for assistance Caution Ensure that all power is removed from the...

Страница 76: ...Electrostatic Discharge and Antistatic Prevention Measures on page 2 9 f Remove the top cover See Section 2 8 Removing the Top Cover on page 2 11 2 Remove the air baffle See Section 4 2 1 Removing the...

Страница 77: ...ard that secures the motherboard tray to the chassis 10 Remove the plastic air flow bezel from between the fans and the motherboard 11 If you are replacing the motherboard only remove the processors a...

Страница 78: ...ollow antistatic practices as described in Section 2 7 Performing Electrostatic Discharge and Antistatic Prevention Measures on page 2 9 1 Power off the server See Section 2 4 Powering Off the Server...

Страница 79: ...included with the grease FIGURE 4 14 Required Pattern for Thermal Grease Application 7 Install the plastic air flow bezel between the fans and the motherboard 8 Install the processor heat sinks See S...

Страница 80: ...n the Server on page 6 5 d Power on the server See Section 6 4 Powering On the Server on page 6 5 15 After you replace the board FRU use the servicetool command to update FRU information about the boa...

Страница 81: ...ommand with options The options are defined in the table below servicetool fru_update serviceprocessor OtherOptions value Option Description board_replaced BOARD Update FRU information for BOARD after...

Страница 82: ...wn NOW Sending SIGTERM to all processes 4 7 2 Restoring Product Information From the FRUID PROM 1 In Escalation mode in ILOM view product information on the FRUID PROM that is on the Power Distributio...

Страница 83: ...4 5f 6e H chassis part_n 000004a0 75 6d 62 65 72 20 35 34 30 2d 37 36 31 38 2d 58 umber 540 7618 X 000004b0 58 0a 5d f3 b7 f3 b7 00 00 00 00 00 00 00 00 00 X 000004c0 00 00 00 00 00 00 00 00 00 00 00...

Страница 84: ...erver and processors 4 8 1 Processor Fault Remind Button If you are replacing a faulty processor press the Remind button on the motherboard to locate the processor that you want to replace The faulty...

Страница 85: ...n and moving to the side and then rotating upward 6 Open the pressure frame 7 Remove the processor 8 Place the removed processor in an anti static package Caution Avoid damaging the pins on the proces...

Страница 86: ...ngage the lever by rotating downward and slipping under the catch 9 Using the supplied grease syringe empty the syringe on to the processor in a star shaped pattern 10 Smooth the grease into a thin ev...

Страница 87: ...ge 2 11 2 Remove the shipping cover from socket 3 Clean the top of the processor with the provided alcohol wipe 4 Place the processor in the socket with the correct orientation 5 Lower the pressure pl...

Страница 88: ...ng CMOS NVRAM Using a Jumper on page 4 36 4 9 1 Overview You can reset a password from the BIOS screen or with a jumper You can also clear the NVRAM or BIOS Password by changing the J1802 jumper posit...

Страница 89: ...osition on page 2 5 4 Attach an antistatic wrist strap See Section 2 7 Performing Electrostatic Discharge and Antistatic Prevention Measures on page 2 9 5 Remove the top cover See Section 2 8 Removing...

Страница 90: ...ls and Drivers CD You need the following Tools and Drivers CD Bootable USB flash device 4 10 1 Reinstalling The Default SP Software Image From The Tools And Drivers CD This emergency flash recovery pr...

Страница 91: ...e is booted run the following command socflash p 1 f sp binary file For Example socflash p 1 f g12n bin If you want to back up the current flash content run following command socflash p 1 f sp binary...

Страница 92: ...ry procedure returns the SP to default configuration 5 Press F2 to enter system BIOS and verify that the flash device is in the boot order 6 After a successful flash remove the flash drive from the US...

Страница 93: ...11 2 NMI Dump Switch The NMI button is the center button of the row of 3 hidden recessed buttons on the back of the motherboard The button for this switch can be pushed by sticking a paper clip or si...

Страница 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...

Страница 95: ...3 Servicing the Drives Cage on page 5 7 FRU Section 5 4 Servicing the Drives Backplane on page 5 11 FRU Section 5 5 Servicing the Front Control Panel Light Pipe Assembly on page 5 13 FRU Section 5 6 S...

Страница 96: ...Remove media from the drive 2 Power off the server See Section 2 4 Powering Off the Server on page 2 4 3 Attach an antistatic wrist strap See Section 2 7 Performing Electrostatic Discharge and Antist...

Страница 97: ...1 Slide the DVD USB module into the front of the chassis until it seats FIGURE 5 2 2 Install the drive you removed during the DVD USB module removal procedure See Section 3 2 5 Installing a Hard Driv...

Страница 98: ...ard or to access the drives data cables in the Sun Fire X4140 Server Note FRU This field replaceable unit should be replaced only by qualified service technicians Contact your Sun Service representati...

Страница 99: ...er from the rack See Section 2 6 Removing a Server From the Rack on page 2 7 d Attach an antistatic wrist strap See Section 2 7 Performing Electrostatic Discharge and Antistatic Prevention Measures on...

Страница 100: ...the board into its mushroom standoffs in the chassis floor and slide the board to the right into the paddle card FIGURE 5 4 FIGURE 5 4 Installing a Fan Power Board 2 Secure the board to the chassis w...

Страница 101: ...You must remove the drive cage to access the following components Drives backplane Front control panel light pipe assemblies Note FRU This field replaceable unit should be replaced only by qualified s...

Страница 102: ...moving them from the system You will need to install the drives in the correct locations when reassembling the system 3 If you are servicing the drive backplane remove the DVD USB module See Section 5...

Страница 103: ...ponents 5 9 FIGURE 5 5 Removing the Drives Cage 5 3 2 Installing the Drives Cage 1 Connect the drives data cables Press the connector into its socket until it snaps into place 2 Position the drives ca...

Страница 104: ...th the paddle card connector FIGURE 5 6 2 4 Replace the No 2 Phillips screws securing the drives cage to the chassis FIGURE 5 6 3 Two screws secure the disk cage to each side of the chassis 5 Install...

Страница 105: ...DVD USB Module on page 5 3 11 Reconnect the power cord or cords to the power supply or supplies Verify that the AC Present LED is lit See Section 6 4 Powering On the Server on page 6 5 12 Power on th...

Страница 106: ...retention hooks 4 Place the drives backplane on an antistatic mat 5 4 2 Installing the Drives Backplane 1 Slide the backplane under the retention hooks on the drives cage FIGURE 5 8 2 Install the two...

Страница 107: ...e 5 5 Servicing the Front Control Panel Light Pipe Assembly You must remove the drives backplane to service the front control panel light pipe assemblies Note FRU This field replaceable unit should be...

Страница 108: ...1 3 Remove the two No 2 Phillips screws securing the front control panel light pipe assembly to the drives cage FIGURE 5 9 4 Slide the light pipe assembly out of the drives cage FIGURE 5 9 Removing th...

Страница 109: ...s the paddle card Note FRU This field replaceable unit should be replaced only by qualified service technicians Contact your Sun Service representative for assistance Caution The system supplies power...

Страница 110: ...ut of the system 7 Place the PDB bus bar assembly on an antistatic mat FIGURE 5 10 Removing the Power Distribution Board 5 6 2 Installing the Power Distribution Board 1 Lower the PDB bus bar assembly...

Страница 111: ...Distribution Board 5 Install the power supplies Slide each power supply into its bay until it locks into place See Section 3 4 4 Installing a Power Supply on page 3 17 6 Install the motherboard assem...

Страница 112: ...Assembly on page 4 22 2 Remove the power distribution board See Section 5 6 1 Removing the Power Distribution Board on page 5 15 3 Remove the fan power boards See Section 5 2 1 Removing a Fan Power Bo...

Страница 113: ...rds See Section 5 2 2 Installing a Fan Power Board on page 5 6 5 Install the power distribution board See Section 5 6 2 Installing the Power Distribution Board on page 5 16 6 Install the motherboard a...

Страница 114: ...4 Powering Off the Server on page 2 4 b Disconnect the power cord or cords from the power supply or supplies See Section 2 4 Powering Off the Server on page 2 4 c Slide the server out of the rack See...

Страница 115: ...the connector into the connector on the HBA card that is closest to the gold fingers port 0 2 Install the disk 4 7 cable a Plug the backplane connector into the Hard Disk Drive backplane b Route the c...

Страница 116: ...tenance Position on page 2 5 d Remove the top cover See Section 2 8 Removing the Top Cover on page 2 11 e Attach an antistatic wrist strap See Section 2 7 Performing Electrostatic Discharge and Antist...

Страница 117: ...lug the backplane connector into the Hard Disk Drive backplane b Route the cable over the Disk 0 3 cable in the same channel through the midwall c Plug the connectors into the three connectors on the...

Страница 118: ...ords from the power supply or supplies See Section 2 4 Powering Off the Server on page 2 4 c Slide the server out of the rack See Section 2 5 Extending the Server to the Maintenance Position on page 2...

Страница 119: ...e Boards and Components 5 25 FIGURE 5 14 Removing the PDB Cable 5 8 6 Installing a PDB Cable To install a Power Distribution Board cable 1 Remove the PDB cable 2 Inspect the motherboard pin field to e...

Страница 120: ...ld Gently press the connector down until seated If you feel significant resistance stop and check the pin alignment 6 Return the server to operation a Install the top cover See Section 6 1 Installing...

Страница 121: ...s chapter Section 6 1 Installing the Top Cover on page 6 2 Section 6 2 Reinstalling the Server in the Rack on page 6 3 Section 6 3 Returning the Server to the Normal Rack Position on page 6 4 Section...

Страница 122: ...Place the top cover on the chassis Set the cover down so that it hangs over the rear of the server by about an inch 25 4 mm 2 Slide the top cover forward until it seats FIGURE 6 1 3 Close the fan cove...

Страница 123: ...vy Two people might be required to carry the chassis and install it in the rack 1 On the rack ensure that the slide rails are extended 2 Place the ends of the chassis mounting brackets into the slide...

Страница 124: ...e position use this procedure to return the server to the normal rack position 1 Release the slide rails from the fully extended position by pushing the release tabs on the side of each rail FIGURE 6...

Страница 125: ...nstallation Guide which is shipped with the system and is also available online To connect power cords and apply power to the server 1 Connect the power cord or cords to the power supply or supplies o...

Страница 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...

Страница 127: ...ignments Topics covered in this appendix include Section A 1 Serial Management Port Connector on page A 2 Section A 2 Network Management Port Connector on page A 3 Section A 3 Video Connector on page...

Страница 128: ...on the motherboard and can be accessed from the rear panel This port is the default connection to the system console FIGURE A 2 Serial Management Connector Diagram TABLE A 1 Serial Management Connecto...

Страница 129: ...ccessed from the rear panel This port needs to be configured prior to use FIGURE A 3 Network Management Connector Diagram TABLE A 2 Network Management Connector Signals Pin Signal Description Pin Sign...

Страница 130: ...e rear panel FIGURE A 4 Video Connector Diagram TABLE A 3 Video Connector Signals Pin Signal Description Pin Signal Description 1 Red Video 9 KEY 2 Green Video 10 Sync Ground 3 Blue Video 11 Monitor I...

Страница 131: ...located on the motherboard in a double stacked layout and can be accessed from the rear panel FIGURE A 5 USB Connector Diagram TABLE A 4 USB Connector Signals Pin Signal Description Pin Signal Descrip...

Страница 132: ...The Ethernet interfaces operate at 10 Mbit sec 100 Mbit sec and 1000 Mbit sec FIGURE A 6 Gigabit Ethernet Connector Diagram TABLE A 5 Gigabit Ethernet Connector Signals Pin Signal Description Pin Sig...

Страница 133: ...Memory Testing Works on page B 2 Section B 3 Redirecting Console Output on page B 2 Section B 4 Changing POST Options on page B 3 Section B 5 POST Codes on page B 4 B 1 Introduction The POST is a sys...

Страница 134: ...B 3 for more information 3 The BIOS polls the memory controllers for both correctable and non correctable memory errors and logs those errors into the SP 4 The message BMC Responding appears at the en...

Страница 135: ...and password with administrator privileges The current POST screen appears B 4 Changing POST Options These instructions are optional but you can use them to change the operations that the server perfo...

Страница 136: ...Option ROM is displayed The two settings for this option are as follows Force BIOS Remove the Sun logo and display Option ROM output Keep Current Do not remove the Sun logo The Option ROM output is no...

Страница 137: ...gs default to the original state specified at the factory C 1 1 Using BIOS Menu Items You can access BIOS configuration screens from the following interfaces Use a USB keyboard and VGA monitor connect...

Страница 138: ...scroll through a menu Use the Tab key to move back and forth across columns 3 Press Enter to select the field A dialog box shows the available options 4 Modify the setup field and close the screen 5...

Страница 139: ...USB PCI MPS and other information Section C 2 2 BIOS Advanced Menu Screens on page C 6 PCI PnP Configuration information for PCI PnP and other information Section C 2 3 BIOS PCI PnP Menu Screens on p...

Страница 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...

Страница 141: ...the screen items and selections shown are subject to change over the life of the product All settings are set to the optimal default at startup C 2 1 BIOS Main Menu Screens The BIOS Main screens provi...

Страница 142: ...M MPS PCI USB Remote Access and other system information Note The term BMC that may be displayed on some screens refers to the SP service processor Note Refer to the Sun Fire X4140 X4240 and X4440 Ser...

Страница 143: ...Appendix C BIOS Screens C 7 FIGURE C 4 BIOS Setup Utility Advanced CPU Configuration FIGURE C 5 BIOS Setup Utility Advanced IDE Configuration...

Страница 144: ...C 8 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 6 BIOS Setup Utility Advanced Hyper Transport Configuration FIGURE C 7 BIOS Setup Utility Advanced ACPI Settings...

Страница 145: ...Appendix C BIOS Screens C 9 FIGURE C 8 BIOS Setup Utility Advanced ACPI Configuration Advanced ACPI Configuration FIGURE C 9 BIOS Setup Utility Advanced ACPI Configuration Chipset ACPI Configuration...

Страница 146: ...C 10 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 10 BIOS Setup Utility Advanced Event Logging Details View FIGURE C 11 BIOS Setup Utility Advanced Event Logging Details Mark...

Страница 147: ...Appendix C BIOS Screens C 11 FIGURE C 12 BIOS Setup Utility Advanced Event Logging Details Clear FIGURE C 13 BIOS Setup Utility Advanced IPMI 2 0 Configuration...

Страница 148: ...Fire X4140 Server Service Manual September 2010 FIGURE C 14 BIOS Setup Utility Advanced IPMI 2 0 Configuration System Event Logs SEL FIGURE C 15 BIOS Setup Utility Advanced IPMI 2 0 Configuration Rel...

Страница 149: ...Appendix C BIOS Screens C 13 FIGURE C 16 BIOS Setup Utility Advanced IPMI 2 0 Configuration Clear BMC SEL FIGURE C 17 BIOS Setup Utility Advanced IPMI 2 0 Configuration LAN Configuration...

Страница 150: ...Server Service Manual September 2010 FIGURE C 18 BIOS Setup Utility Advanced IPMI 2 0 Configuration Set PEF Configuration FIGURE C 19 BIOS Setup Utility Advanced IPMI 2 0 Configuration Set PEF Config...

Страница 151: ...Appendix C BIOS Screens C 15 FIGURE C 20 BIOS Setup Utility Advanced IPMI 2 0 Configuration PEF Action Global Control FIGURE C 21 BIOS Setup Utility Advanced IPMI 2 0 Configuration PEF Event Message...

Страница 152: ...C 16 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 22 BIOS Setup Utility Advanced IPMI 2 0 Configuration BMC Watch Dog Timer Action FIGURE C 23 BIOS Setup Utility Advanced MPS Revision...

Страница 153: ...Appendix C BIOS Screens C 17 FIGURE C 24 BIOS Setup Utility Advanced PCI Express Configuration FIGURE C 25 BIOS Setup Utility Advanced Remote Access Configuration...

Страница 154: ...C 18 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 26 BIOS Setup Utility Advanced USB Configuration FIGURE C 27 BIOS Setup Utility Advanced USB Mass Storage Device Configuration...

Страница 155: ...ts which can be used for detecting inconsistent and faulty hardware Activating these features on a healthy system can result in an unstable execution and are strictly for trained service personnel s u...

Страница 156: ...GURE C 29 BIOS Setup Utility Advanced PCI PnP Configuration C 2 4 BIOS Boot Menu Screens The BIOS Boot screens allow you to configure the boot device priority hard disk drives and the DVD ROM drive Th...

Страница 157: ...Appendix C BIOS Screens C 21 FIGURE C 30 BIOS Setup Utility Boot FIGURE C 31 BIOS Setup Utility Boot Settings Configuration...

Страница 158: ...C 22 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 32 BIOS Setup Utility Boot Device Priority FIGURE C 33 BIOS Setup Utility Boot Hard Disk Drives...

Страница 159: ...URE C 34 BIOS Setup Utility Boot CD DVD Drives C 2 5 BIOS Security Menu Screens The BIOS Security screens allow you to set or change the user and supervisor passwords The Sun Fire X4140 Server has the...

Страница 160: ...FIGURE C 35 BIOS Setup Utility Security Change Supervisor Password C 2 6 BIOS Chipset Menu Screens The BIOS Server screens allow you to configure Server advanced chipset settings if applicable The Sun...

Страница 161: ...Appendix C BIOS Screens C 25 FIGURE C 36 BIOS Setup Utility Chipset FIGURE C 37 BIOS Setup Utility Chipset Northbridge Configuration...

Страница 162: ...C 26 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 38 BIOS Setup Utility Chipset Northbridge Memory Configuration FIGURE C 39 BIOS Setup Utility Chipset Northbridge ECC Configuration...

Страница 163: ...Appendix C BIOS Screens C 27 FIGURE C 40 BIOS Setup Utility Chipset Northbridge DRAM Timing Configuration FIGURE C 41 BIOS Setup Utility Chipset Northbridge VID Configuration...

Страница 164: ...C 28 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 42 BIOS Setup Utility Chipset Southbridge Configuration FIGURE C 43 BIOS Setup Utility Chipset I055 Bridge Configuration...

Страница 165: ...Menu Screens The BIOS Exit screens allow you to save changes and exit discard changes and exit discard changes or load optimal or failsafe defaults The Sun Fire X4140 Server has the following BIOS Exi...

Страница 166: ...C 30 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 45 BIOS Setup Utility Exit Save Configuration Changes FIGURE C 46 BIOS Setup Utility Help...

Страница 167: ...ironment 3 18 configuring BIOS C 1 console output redirecting B 2 corrupt SP recovering from 4 37 CRU 3 1 D DIMM guidelines 4 3 layout 4 4 drive fillers 3 8 DVD USB module installing 5 3 removing 5 2...

Страница 168: ...button 3 13 M maintenance position 2 5 2 8 N NMI 4 39 P POST changing options B 3 codes table B 4 overview B 1 redirecting console output B 2 Power Supply Failure LED 3 14 powering off server from se...