4-30
BRC-300/300P
BRU-300/300P
Does this unit
correctly function when
another BRBK-302 is
connected to the slot
on the main unit ?
No
Yes
Is the switch S8001
correctly set on the
SD board ?
Yes
No
Go to
5
(Next page)
Does this unit
correctly function
when connected to a
normal BRC-300/P ?
Yes
BRBK-302 connection
failure
Connect this unit securely
to the BRC-300/P or the
BRU-300/P.
No
Check the model
connected to this unit.
BRU-300/P
Does the monitor
support SDI input ?
Yes
Use the monitor
supporting SDI input.
No
Is only one BRBK-302
connected ?
Yes
No
Turn off the power of the
BRU-300/P, and remove
one of the cards.
Set the switch S8001 on
the SD board correctly.
f-1
BRC-300/P failure
Go to a-10.
BRU-300/P failure
Go to c-6.
BRC-300/P
4-6-2. BRBK-302
f-1.
Image is not displayed.
S8001
SD-50 BOARD (SIDE A)
[OK]