4-24
BRC-300/300P
BRU-300/300P
Are the communication
method and the baud
rate correctly set for the
camera ?
Is the BRC-300/P used ?
FFC: Flexible flat cable
Yes
Yes
Have you exited the
menu on the monitor ?
Yes
Is the camera address
of the BRC-300/P
automatically set ?
Yes
No
No
Set correctly the
communication method
(RS-232C/RS-422) and the
baud rate (38400/9600) for
the camera, and restart the
system.
Exit the menu, and perform
operation checks.
n
The pan/tilt operations are
not available while the
menu is being displayed.
No
No
Does the CAMERA
button corresponding
to the camera address
of the BRC-300/P
light up?
Yes
Press the CAMERA button
corresponding to the
camera address of the
BRC-300/P to light it up,
and perform operation
checks.
No
Go to
3
(Next page)
Is the cable between
the camera and this unit
correctly connected ?
Yes
No
Connect correctly the cable
between the camera and
this unit.
Connect correctly the FFC
between the MD and SW
boards.
No
Is the FFC between
the MD and SW boards
correctly connected ?
Yes
d-2
4-5-2. Communication Trouble
d-2.
Camera operations are not available.