1-17
BRC-300/300P
BRU-300/300P
SY-314 Board
Ref. No.
Bit
Name
Description
Factory setting
S1001
1
Camera address setting switch
Sets a camera address.
*
0 (All OFF)
2
3
4
—
Factory use
OFF
S1002
1
—
Factory use
OFF
2
RS-232C/RS-422
Selects RS-232C or RS-422.
OFF (RS-232C)
ON:
RS-422
OFF: RS-232C
3
9600bps/38400bps
Sets communication baud rate.
OFF (9600 bps)
ON:
38400 bps
OFF: 9600 bps
4
IR OUT
Sets infrared output to ON/OFF.
OFF
S1003
1
MYCOM WRITING
Set this to ON only when writing the
OFF
firmware without the EX-947 board.
2
JTAG SELECT
Factory use
OFF
3
OPE/ADJ MODE SELECT
Switches operation modes. (Normal/
Normal mode
Adjustment)
(OFF)
n
Set this to ON only when adjusting
without the EX-947 board.
ON:
Adjustment mode
OFF: Normal mode
4
—
Factory use
OFF
S1004
—
SUPER RESET
When the power is turned on while this
—
switch is pressed, the menu settings and
adjustment values are initialized.
*
: Camera address settings
Camera addresses
0
1
2
3
4
5
6
7
S1001-1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
S1001-2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
S1001-3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
S1001
S1002
S1003
S1004
SY-314 BOARD (SIDE B)