Operators Tools
7-12
7SJ63 Manual
C53000-G1140-C120-1
7.1.2
Statistics
The messages in statistics are counters for the accumulation of interrupted current by
each of the breaker poles, the number of trips issued by the device to the breaker, and
the operating hours of the breaker and protected equipment. The interrupted currents
are in primary terms.
Statistics can be viewed on the LCD of the device, or on a PC running DIGSI
®
4 and
connected to the operating or service interface.
A password is not required to read statistics; however, a password is required to
change or delete the statistics.
7.1.2.1
Retrieve the Statistics
For each trip command initiated by a protective element of the device, the magnitude
of interrupted current for each circuit breaker pole is determined and recorded. The
current magnitudes are added to previously interrupted currents, and the values are
accumulated. The number of circuit breaker operations is counted in the device based
on the feedback information from the circuit breaker contacts. A precondition is that
binary inputs are wired to the circuit breaker auxiliary contacts, and these binary inputs
are masked for counting.
In addition, the operating hours for the protected equipment are counted. The protect-
ed equipment is considered to be in operation whenever the current threshold, set un-
der Address 0212 (
%NU&ORVHG,0,1
), is exceeded by at least one phase current.
The counter are retained during a loss of power supply voltage.
From the
Device Front
With a device ready for operation, first press the
key. The
0$,10(18
appears.
The first menu item
$QQXQFLDWLRQ
is marked.
Press the
key to enter the
$1181&,$7,21
sub-menu (see Figure 7-1).
Use the
key to select the item
6WDWLVWLF
, and switch to the list of statistics values
using the
key. The
67$7,67,&
list appears. See figure 7-14.
Figure 7-14
Statistics Viewed from the Front Display
From PC with
DIGSI
®
4
Under Annunciation (Figure 7-2), the statistics can be found by double clicking. Dou-
ble click on
6WDWLVWLF
. The sub-menus
6WDWLVWLF
and
6HW3RLQWV6WDWLV
WLF
appear in the data window. By double clicking on one of the two alternatives, the
associated contents are displayed in another window. See Figure 7-15.
MENU
67$7,67,&6
Σ
,D N$
Σ
,E N$
Etc.
:
www
. ElectricalPartManuals
. com
Содержание siprotec 7SJ63
Страница 16: ...xiv 7SJ63 Instruction Manual C53000 G1140 C120 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 28: ...Introduction 1 12 7SJ63 Manual C53000 G1140 C120 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 112: ...SIPROTEC 4 Devices 4 38 7SJ63 Manual C53000 G1140 C120 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 346: ...Functions 6 182 7SJ63 Manual C53000 G1140 C120 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 494: ...Technical Data 10 48 7SJ63 Manual C53000 G1140 C120 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 604: ...Index Index 6 7SJ63 Instruction Manual C53000 G1140 C120 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...