Parameter list
7.2 Parameter list
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
231
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
1
Reset fault
Note:
See P0947 (last fault code)
Automatically reset to 0.
P3984
Client telegram off time
[ms]
100 -
10000
1000
T
-
-
U16
3
Defines time after which a fault will be generated (F73) if no telegram is received from the client.
Dependency: Setting 0 = watchdog disabled
r3986[0...1]
Number of parameters
-
-
-
-
-
U16
4
Number of parameters on the inverter.
Index:
[0]
Read only
[1]
Read & write
P7844
Acceptance Test,
Confirmation
0 - 2
0
T
-
-
U16
3
After an automatic download from MMC at startup, this parameter will be automatically set to 1. Also a
fault F395 will be set.
With setting to P7844 = 0 you quit F395 and confirm the parameter settings. Setting this parameter to 2 is
only possible if an automatic download has been performed at startup. In this case the download will be
undone and the previously stored parameters will be enabled.
0
Acceptance Test / Confirmation ok.
1
Acceptance Test / Confirmation is pending
2
Undo Clone
Note:
If no automatic download from MMC has been performed during startup the setting 2 is not possible.
P8458
Clone control
0 - 2
2
T
-
-
U16
3
This parameter specifies whether a cloning at startup will be performed. The File clone00.bin will be used.
If no MMC is inserted there will be a normal startup.
0
No Startup Clone
1
Once Startup Clone
2
Always Startup Clone
Note:
Default value is 2. After first cloning the parameter is set to 0. If a MMC is inserted without a valid file the
inverter will set a fault F61 / F63 / F64 which can only be cleared by a power-cycle. The fault is signaled by
a flashing RUN LED (Commissioning). The SF LED is not activated. P8458 will not be changed by
performing a factory reset.
P8553
Menu type
0 - 1
0
U, T
-
-
U16
1
Selects whether to have menus with no text or menus with some text on the BOP.
0
Menus with no text
1
Menus with some text
Содержание SINAMICS V20 Series
Страница 4: ...Preface SINAMICS V20 Inverter 4 Operating Instructions 07 2012 A5E03728167 ...
Страница 12: ...Safety instructions SINAMICS V20 Inverter 12 Operating Instructions 07 2012 A5E03728167 ...
Страница 232: ...Parameter list 7 2 Parameter list SINAMICS V20 Inverter 232 Operating Instructions 07 2012 A5E03728167 ...
Страница 274: ...Index SINAMICS V20 Inverter 274 Operating Instructions 07 2012 A5E03728167 ...