Commissioning
5.6 Function commissioning
SINAMICS V20 Inverter
66
Operating Instructions, 07/2012, A5E03728167
Parameter
Boost type
Description
P1312
Starting boost [%]
This parameter applies a constant linear offset relative to P0305 (rated motor
current) to active V/f curve (either linear or quadratic) after an ON command
and is active until:
•
ramp output reaches setpoint for the first time respectively
•
setpoint is reduced to less than present ramp output
Range: 0.0 ... 250.0 (factory default: 0.0)
The voltage boost is only effective when accelerating for the first time
(standstill).
9
9
Q
3
I
Q
3
I
PD[
3
I
9
6WDUW%RRVW
9
PD[
I
VHW
2
XW
SX
WYR
OWD
JH
1R
UP
DO
9
I
5)*
DFWLYH