Parameter list
7.2 Parameter list
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
177
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
2
Control stop
Note:
P1256 = 0:
Maintain DC-link voltage until mains is returned or inverter is tripped with undervoltage. The frequency is
kept above the frequency limit provided in P1257.
P1256 = 1:
Maintain DC-link voltage until mains is returned or inverter is tripped with undervoltage or pulses are
disabled when frequency falls below the limit in P1257.
P1256 = 2:
This option ramps down the frequency to standstill even when mains return.
If mains do not return, frequency brought down under the control of Vdc_min controller until P1257 limit.
Then pulses are disabled or undervoltage has occurred. If mains return, then an OFF1 is active until
P1257 limit. Then pulses are disabled.
P1257[0...2] Frequency limit for
kinetic buffering [Hz]
0.00 -
599.00
2.50
U, T
-
DDS
Float 3
Frequency which kinetic buffering (KIB) either hold speed or disable pulses depending on P1256.
P1300[0...2] Control mode
0 - 19
0
C(1), T
-
DDS
U16
2
Parameter to select the control method. Controls relationship between speed of motor and voltage
supplied by inverter.
0
V/f with linear characteristic
1
V/f with FCC
2
V/f with quadratic characteristic
3
V/f with programmable characteristic
4
V/f with linear eco
5
V/f for textile applications
6
V/f with FCC for textile applications
7
V/f with quadratic eco
19
V/f control with independent voltage setpoint
I
Q
I
9
9Q
3
3
Note:
P1300 = 1: V/f with FCC (flux current control)
•
Maintains motor flux current for improved efficiency
•
If FCC is chosen, linear V/f is active at low frequencies
P1300 = 2: V/f with a quadratic characteristic
•
Suitable for centrifugal fans / pumps
P1300 = 3: V/f with a programmable characteristic
•
User defined characteristic (see P1320)
P1300 = 4: V/f with linear characteristic and Economy Mode
•
Linear characteristic with Economy Mode
•
Modifies the output voltage to reduce power consumption
Содержание SINAMICS V20 Series
Страница 4: ...Preface SINAMICS V20 Inverter 4 Operating Instructions 07 2012 A5E03728167 ...
Страница 12: ...Safety instructions SINAMICS V20 Inverter 12 Operating Instructions 07 2012 A5E03728167 ...
Страница 232: ...Parameter list 7 2 Parameter list SINAMICS V20 Inverter 232 Operating Instructions 07 2012 A5E03728167 ...
Страница 274: ...Index SINAMICS V20 Inverter 274 Operating Instructions 07 2012 A5E03728167 ...