Parameter list
7.2 Parameter list
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
225
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
r3113.0...15 CO / BO: Fault bit array -
-
-
-
-
U16
1
Gives information about actual fault.
Bit
Signal name
1 signal
0 signal
00
Inverter error
Yes
No
01
Power line failure
Yes
No
02
Intermediate circuit power voltage
Yes
No
03
Error power electronics
Yes
No
04
Inverter overtemperature
Yes
No
05
Earth leakage
Yes
No
06
Motor overload
Yes
No
07
Bus fault
Yes
No
09
Reserved
Yes
No
10
Fault internal communication
Yes
No
11
Motor current limit
Yes
No
12
Supply failure
Yes
No
13
Reserved
Yes
No
14
Reserved
Yes
No
15
Other error
Yes
No
P3350[0...2]
Super torque modes
0 - 3
0
T
-
-
U16
2
Selects the super torque function. Three different super torque modes are available:
•
Super Torque - applies a pulse of torque for a given time to help start the motor
•
Hammer Start - applies a sequence of torque pulses to help start the motor
•
Blockage Clearing - performs a reverse-forward operation to clear a pump blockage
Super Torque Operation:
3
3
3
3
3
%RRVW
2XWSXWIU]
6XSHUWRUTXHUDPSWLPH
5DPSXSWLPH
WLPH
WLPH
Содержание SINAMICS V20 Series
Страница 4: ...Preface SINAMICS V20 Inverter 4 Operating Instructions 07 2012 A5E03728167 ...
Страница 12: ...Safety instructions SINAMICS V20 Inverter 12 Operating Instructions 07 2012 A5E03728167 ...
Страница 232: ...Parameter list 7 2 Parameter list SINAMICS V20 Inverter 232 Operating Instructions 07 2012 A5E03728167 ...
Страница 274: ...Index SINAMICS V20 Inverter 274 Operating Instructions 07 2012 A5E03728167 ...