4.1.4
Intpo
Table 4-7
SIMATIC S7 → SIMOTION, Trolley
PZD
Signal name
Unit
Format
Remark
1
STW1_PLC_Intpo
-
WORD
Control word
See table below
2
LIST_IDX
-
Byte 1
Received interpolation point number
The interpolation point number selects a particular interpolation
point and returns its hoist and trolley positions. The interpolation
point number must not be greater than the number of existing
interpolation points. Otherwise an error is returned.
2
-
-
Byte 2
Reserved
3-5
-
Reserved
Table 4-8
STW1_PLC_Intpo
Bit
Signal name
Remark
0
ENABLE
Activate transfer of obstacles.
1-15 -
Reserved
4.1.5
TLS
Table 4-9
SIMATIC S7 → SIMOTION, TLS
PZD
Signal name
Unit
Format
Remark
1
STW1_PLC_TLS
-
WORD
Control word 1
See table below
2
STW2_PLC_TLS
-
WORD
Control word 2
See table below
3-4
ActPos_cylinder_A
1
DINT
Cylinder A position
5-6
ActPos_cylinder_B
1
DINT
Cylinder B position
7-8
ActPos_cylinder_C
1
DINT
Cylinder C position
9-10
ActPos_cylinder_D
1
DINT
Cylinder D position
11-12
SkewAngle_ext_for_TLS
cgr
DINT
External skew angle for TLS positioning
(see Chapter Control of the modes and the skew damping
for the hydraulic system (Page 260)
13-14
-
Reserved
15-16
SkewPos_ext_for_Eaxis
mm
DINT
External skew position for electric drive
(see Chapters Controlling movement of the electric drive
(Page 259) and Controlling travel and skew damping with
Communication interface to SIMATIC S7
4.1 SIMATIC S7 → SIMOTION D for AddOn
SC integrated STS, GSU
90
Operating Instructions, 07/2019, A5E48271265B AA