Scenarios B and C
Scenarios B and C define a learning travel if only the landside or waterside spreader is locked
in double-spreader operation.
6SUHDGHU
$
6SUHDGHU
%
&XUUHQWKRLVWSRVLWLRQORZHUHGJHRIVSUHDGHU
&RQWDLQHU
$
3P
3
,PPHUVLRQSRLQW
P108
Maximum container height
2 m
Minimum container height
Figure 6-20
Forming the immersion point - scenarios B and C
Explanation of the diagram:
The immersion point is set at the "current hoist position (lower edge of spreader) + P108 – 2 m".
The immersion point is lowered by P108 (maximum container height) during unlocking.
The immersion point thus behaves exactly as if two twistlock bits were set.
Scenario D
Scenario D defines a learning travel if all of the containers are locked. It is applicable to all
spreader constellations.
6SUHDGHU
$
6SUHDGHU
%
&XUUHQWKRLVWSRVLWLRQORZHUHGJHRIVSUHDGHU
&RQWDLQHU
$
3P
3
&RQWDLQHU
%
3
,PPHUVLRQSRLQW
P108
Maximum container height
2 m
Minimum container height
Figure 6-21
Forming the immersion point - scenario D
Explanation of the diagram:
The immersion point is set at the "current hoist position (lower edge of spreader) + P108 – 2 m".
Sway Control function description
6.10 Blocked regions
SC integrated STS, GSU
184
Operating Instructions, 07/2019, A5E48271265B AA