Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
bo_zsw1_pos_in_safety_area
IN
BOOL
common_SC_pos_in_safety_area
Bit 9 of status word 1
bo_zsw1_Pos_In_BR_Man
IN
BOOL
common_sc_pos_in_br_man
Bit 10 of status word 1
b32Error1
IN
DWORD common_sc_error1
Error area 1
b32Error2
IN
DWORD common_sc_error2
Error area 2
b32Info_No_Auto_Start
IN
DWORD common_sc_info_no_auto_start
Information area for SAM
mode start
i8Parset_OUT
IN
SINT
common_SC_ParSet_OUT
Return value for parameter
set
i32impnt
OUT DINT
common_SC_Impnt
Current immersion point
Common_IO_PQW
OUT ARRAY
[0..11]
OF word
addon_common_send
Output array for the Com‐
3.3.2.3
FB_HoistPLCToAddOn
Symbol (FBD representation)
)%B+RLVW3/&7R$GG2Q
$55$<
+RLVWB,2B3,:
EBVWZ
ERBVWZB5HOHDVH
ERBVWZB7UDYHO
ERBVWZB20B3RV
ERBVWZB20B6SHHG
ERBRLVWB&RQWURO
ERBVWZB/6B83
ERBVWZB/6B'1
:25'
%22/
%22/
%22/
%22/
%22/
%22/
%22/
%22/
ERBVWZB3UH/6B83
ERBVWZB3UH/6B'1
ERBVWZB%UDNHBFORVHG
%22/
%22/
,17
L2YHUULGH
,17
L2IIVHW
Figure 3-17
FB_HoistPLCToAddOn
Task
The "FB_HoistPLCToAddOn" block reads the input area from the PROFIBUS DP / PROFINET
PN for the Hoist block and separates the array into words and bits.
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA