
Figure 8-21
Explorer function
Prerequisite for the correct operation is the correct assignment of the IP address to the
connected device in the "Options/Interface" CeCOMM menu function.
8.7
Diagram - trace function
The "Diagram" function is a user interface for recording, loading and saving characteristic and
signal curves.
Basically there are two diagram types:
● Time diagram
This diagram shows the signal flows (e.g. velocity, distance, degree) over time. All curves
of the calculated and actual velocities and distances (upper area) as well as all states of the
input/output bits (lower area) can be tracked.
● x/y diagram
The distance curves for two drives in the x/y plane with displayed blocked regions can be
monitored.
The recorded measured values are used for both diagram types. F11 or F12 can be used to
switch between the diagram types.
SIMOCRANE CeCOMM commissioning and diagnostic program
8.7 Diagram - trace function
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
289