Figure 9-3
Monitor function, "Status of drives" [3] display screen
Representation of the bit states of the prelimit/limit switches on the display screen "Status of the
drives [3]"
Table 9-1
Explanation of display screen [3]
1+/1+
Prelimit switch forward and limit switch forward responded
1+
Prelimit switch forward responded
0
No limit switch responded
1-
Prelimit switch backward responded
1-/1-
Prelimit switch backward and limit switch backward responded
2
Prelimit switch forward and prelimit switch backward responded
0/2
Limit switch forward and limit switch backward responded
2/2
All limit switches responded
9.3.7
Setting up FTP file access
With SIMOTION firmware V4.4 and higher, a user name and password must be stored on the
CF card for the use of FTP, web services or access-protected pages. If this has already been
set up, you can skip the next step and continue with "Setting user name and password in
SIMOCRANE CeCOMM".
Commissioning AddOn Software
9.3 Commissioning requirements for AddOn software
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
325