3.3.2.9
FB_TLSPLCToAddOn
Symbol (FBD representation)
)%B7/63/&7R$GG2Q
$55$<
7/6B,2B3,:
EB&:
EB&:
U3RVB&\OB$
U3RVB&\OB%
U3RVB&\OB&
U3RVB&\OB'
L6B6NHZB([WHUQ
U6HW3RVB6NHZ$[LV
:25'
:25'
/5($/
/5($/
/5($/
/5($/
',17
/5($/
Figure 3-23
FB_TLSPLCToAddOn
Task
The "FB_TLSPLCToAddOn" block reads the input area from the PROFIBUS DP / PROFINET
PN for the DCC_SCTLS2 block and separates the array into words and bits.
Connections
The outputs must be connected using the unit-global variables of the "AddOn" MCC source file
with the inputs of the DCC_SCTLS2 DCC block.
Table 3-27
FB_TLSPLCToAddOn connections
Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
TLS_IO_PIW
IN
Array
[0..15]
OF word
addon_tls_receive
Input array
for the TLS2 block
b16_CW1
OUT WORD
TLS_CW1
Control word 1
b16_CW2
OUT WORD
TLS_CW2
Control word 2
r64Pos_Cyl_A
OUT LREAL
TLS_rpos_a
Cylinder A position
r64Pos_Cyl _B
OUT LREAL
TLS_rpos_b
Cylinder B position
r64Pos_Cyl _C
OUT LREAL
TLS_rpos_c
Cylinder C position
r64Pos_Cyl _D
OUT LREAL
TLS_rpos_d
Cylinder D position
i32S_Skew_Extern
OUT DINT
TLS_iskew_angle_ext
External skew position for TLS
positioning
r64SetPos_SkewAxis
OUT LREAL
TLS_rskewpos_set
Set position of electric skew
drive for external position
mode
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
68
Operating Instructions, 07/2019, A5E48271265B AA