Task
The "FB_TargetsAddOnToPLC" block writes the Targets block to the PROFIBUS DP /
PROFINET PN output area.
Connections
The inputs must be connected using the unit-global variables of the "AddOn" MCC source file
with the outputs of the DCC_SCTARGETS DCC block.
Table 3-30
FB_TargetsAddOnToPLC connections
Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
bo_zsw1_Direction_Land
IN
BOOL
targets_sc_direction_land
Bit 1 of status word 1
bo_zsw1_Direction_Water
IN
BOOL
targets_sc_direction_water
Bit 2 of status word 1
bo_zsw1_Pos_Saved
IN
BOOL
targets_sc_pos_saved
Bit 0 of status word 1
i8Lane_Ship_Load_OK
IN
SINT
targets_SC_Lane_Load_OK
Return the lane number from
which the ship will be loaded
i8Lane_Ship_Unload_OK
IN
SINT
targets_SC_Lane_Unload_OK
Return the lane number from
which the ship will be unloaded
Targets_IO_PQW
OUT ARRAY
[0..5] OF
word
addon_targets_send
Output array for the Targets
block (see Figure 5-13 Address
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU