Connections
Table 3-12
Block DCC_SCTLS2
Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
BCOMMAND_WORD1
IN
UINT
tls_cw1
Control word 1 (see the table be‐
low)
BCOMMAND_WORD2
IN
UINT
tls_cw2
Control word 2 (see the table be‐
low)
RPOS_SKEWAXIS
IN
LREAL
TO: positioningstate.actualposition
Actual position of skew drive
RPOS_A
IN
LREAL
tls_rpos_a
Actual positions of cylinder A
RPOS_B
IN
LREAL
tls_rpos_b
Actual positions of cylinder B
RPOS_C
IN
LREAL
tls_rpos_c
Actual positions of cylinder C
RPOS_D
IN
LREAL
tls_rpos_d
Actual positions of cylinder D
ISKEW_ANGLE_EXT
IN
DINT
tls_iskew_angle_ext
External skew position for the
TLS mode "TLS positioning"
RSKEWPOS_SET
IN
LREAL
tls_rskewpos_set
Set position of skew drive
-
IN
-
Reserved
BSTATUS_WORD1
OUT UINT
tls_sw1
Status word 1
(see the table below)
BSPEED_A_NORM
OUT UINT
tls_bspeed_a_norm
Output velocity cylinder A
BSPEED_B_NORM
OUT UINT
tls_bspeed_b_norm
Output velocity cylinder B
BSPEED_C_NORM
OUT UINT
tls_bspeed_c_norm
Output velocity cylinder C
BSPEED_D_NORM
OUT UINT
tls_bspeed_d_norm
Output velocity cylinder D
IPOS_ACT_TRIM
OUT DINT
tls_ipos_act_trim
Actual position trim
IPOS_ACT_LIST
OUT DINT
tls_ipos_act_list
Actual position list
IPOS_ACT_SKEW
OUT DINT
tls_ipos_act_skew
Actual position skew
IANGLE_OSZ_SKEW
OUT DINT
tls_iangle_osz_skew
Internal model for skew oscilla‐
tion angle [cgr]
BSPEED_SKEWAX‐
IS_NORM
OUT INT
tls_bspeed_skewaxis_norm
Output velocity of skew drive
normalized with P332 and P325
RSPEED_A
OUT LREAL
If the normalized value is used, this in‐
terconnection is not required.
Output velocity of cylinder A in
mm/s
(DCC output only, not included in
PROFINET interface)
RSPEED_B
OUT LREAL
If the normalized value is used, this in‐
terconnection is not required.
Output velocity of cylinder B in
mm/s
(DCC output only, not included in
PROFINET interface)
RSPEED_C
OUT LREAL
If the normalized value is used, this in‐
terconnection is not required.
Output velocity of cylinder C in
mm/s
(DCC output only, not included in
PROFINET interface)
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
49