4.2.6
Targets
Table 4-30
SIMOTION D 435-2 DP/PN → SIMATIC S7, Targets
PZD Signal name
Unit
Format
Remark
1
ZSW1_Targets_PLC
-
WORD
Status word
(see below, Table ZSW1_Targets_PLC)
2
LANE_LOAD_OK
1 ... 99
SINT
Confirmation lane number loading
Confirmation of the lane number for loading
LANE_UNLOAD_OK
1 ... 99
SINT
Confirmation lane number unloading
Confirmation of the lane number for unloading
3-6
-
Reserved
Table 4-31
ZSW1_Targets_PLC
Bit
Signal name
Remark
0
POS_SAVED
Position learning successful
0: Position learning unsuccessful
1: Position learning successful
This bit is used for the confirmation of the successful learning of the positions for parking,
lashing platform, and lane.
1
DIRECTION_LAND
Next target toward landside
0: The next target is not on the landside.
1: The next target is on the landside.
The real direction of trolley movement can be toward the landside or toward the waterside.
Targets from the target generator and external targets are considered.
This bit is set only if the distance between the start and target positions of the trolley is at
least double the positioning accuracy set in P162.
2
DIRECTION_WATER
Next target toward waterside
0: The next target is not on the waterside.
1: The next target is on the waterside.
The real direction of trolley movement can be toward the landside or toward the waterside.
Targets from the target generator and external targets are considered.
This bit is set only if the distance between the start and target positions of the trolley is at
least double the positioning accuracy set in P162.
3-15 -
Reserved
Communication interface to SIMATIC S7
4.2 SIMOTION D for AddOn → SIMATIC S7
SC integrated STS, GSU
106
Operating Instructions, 07/2019, A5E48271265B AA