Table 5-1
I/O address ranges for the AddOn technology
Block
Functions
Length (word) I/O address range
DCC_SCCOMMON
Common
12
2000-2023
DCC_SCHOIST
Hoist
6
2024-2035
DCC_SCTROLLEY
Trolley
6
2036-2047
DCC_SCINTPO
Interpolation points
6
2048-2059
DCC_SCTLS2 (STS only) TLS (STS only)
16
2060-2091
DCC_SCTARGETS
Targets
6
2092-2103
DCC_SCOBSTACLES
Obstacle regions Block1
16
2104-2135
Obstacle regions Block2
16
2136-2167
-
Additional data (AddData_1)
16
2168-2199
-
Additional data (AddData_2)
16
2200-2231
-
Additional data (AddData_3)
6
2232-2243
Enter these addresses in the "I-Device" tab under "Transfer area".
Figure 5-7
I/O peripherals definition in the SIMOTION D435-2 hardware configuration
Configuration
5.5 PROFINET configuration
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
115