Bit no.
Name
Meaning
10
c_out
Extend cylinder C
11
d_out
Extend cylinder D
12
a_in
Retract cylinder A
13
b_in
Retract cylinder B
14
c_in
Retract cylinder C
15
d_in
Retract cylinder D
Error messages
If an error occurs in TLS control mode, the corresponding error bits and error numbers are set
by the block and displayed via SIMOCRANE CeCOMM.
Furthermore, the output "bError" is set at the DCC_SCCOMMON block and the error number
is output at output "IErrorID" (for a description and help, see Chapter Error list AddOn
(Page 374)). If several errors are present, the oldest error will be displayed.
3.3.1.7
DCC_SCINTPO
Symbol
'&&B6&,1732
%22/
%(1$%/(
%&2817
%&855B,';
,326B75
,326B+2
%(5525
%<7(
%<7(
',17
',17
%22/
%<7(
%/,67B,';
Figure 3-12
DCC_SCINTPO
Brief description
The block outputs the calculated interpolation points.
Method of operation
The number of interpolation points for the relevant movement in semi-automatic mode (SAM)
is issued at the output. Consecutive numbers (starting at 1) are assigned internally to the
interpolation points. The relevant hoist and trolley positions are issued at the output depending
on the specified interpolation point number.
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
52
Operating Instructions, 07/2019, A5E48271265B AA