11.2. ALTUS NR2 RTK BASE-ROVER WI-FI CONNECTION
Configure the IPR connection
Setup an IPR (Receive) connection for reception of differential corrections.
On the
‘Communication/IP Settings’ menu, configure and IPR connection with the same port number
configured for the Base station and the IP address
192.168.20.1
as shown in Figure 11-16.
Figure 11-16:
Configure the rover receiver to listen for the diff corr ouptut from
the Base station
Step 4: Verifying the configuration
If both the Base station and rover receivers have been configured correctly, the rover
‘Overview’ tab should show the Wi-Fi connection to the base station and the top panel
positioning mode icon should indicate RTK fixed as shown in Figure 11-17/
Figure 11-17:
If the configuration is correct, the Wi-fi panel should show a
connection to the Base station and the top-panel icon indicate RTK fixed