75
A-08
Wobble frequency hopping (Relative aptitude)
Factory setting
d 0.0
Setting range
d 0.0<->d 50.0%
Unit
0.1%
When it is set to 0, it refers that no frequency hopping occurs.
A-09
Wobble frequency cycle
Factory setting
d 10.0
Setting range
d 0.1<->d 655s
Unit
0.1s
This parameter sets time for a complete work cycle including wobble rising and descending. Never select auto
acceleration/deceleration running cycle in wobble frequency running mode, otherwise fault to wobble frequency cycle
may occur.
A-10
Triangle wave rising time(Relative cycle)
Factory setting
d 50.0
Setting range
d 0.1<->d 99.9%
Unit
0.1%
This parameter sets operation time of wobble frequency rising, which is equivalent to (A-09)×(A-10)(sec), and
operation time of wobble frequency rising shall be (A-09)×(A-10)(sec).
A-11
Wobble frequency machine stop starting mode
Factory setting
d 0
Setting range
d 0
Starting in memorizing state before machine stop
d 1
Restarting
A-12
Wobble state power loss memory
Factory setting
d 0
Setting range
d 0
Memorizing
d 1
Non-memorizing
This parameter shall only be available when A-11 is set to 0 (Starting in memorizing state before machine stop).