53
JOG FWD (d24):
Jog forward run. For relative application, see description of Parameter (1-13, 1-14 and1-15)
JOG REV (d25):
Jog reverse run. For relative application, see description of Parameter (1-13, 1-14 and1-15)
Description of action: When jog function is performed while the inverter is in stop, the jog acceleration and
deceleration time (1-13, 1-14) shall be subject to. Jog run reference shall only be used when the Inverter in stop and
[STOP] key from the digital operation keypad shall be available
Running command shall not be input ON when in JOG running, Or Motor runs with illegal direction.
d26 is reserved.
Wobble frequency function input (d27):
Description of action: If wobble frequency starting is manual, wobble frequency status shall be available when
terminals are closed; when terminals open, wobble frequency function shall be cancelled and the operation
frequency keeps at wobble frequency preset frequency A-02.
Wobble frequency function reset (d28):
Description of action: For both auto and manual selection of wobble frequency function, when this terminal is closed,
wobble frequency state information in memory shall be cancelled, and operation frequency shall be preset; after
opening the terminal, wobble frequency shall restart, and if it was auto input mode, wobble frequency state shall only
be available after wobble frequency delay time.
Inhibiting output (d29. d30):
This function provides the motor drive to receive emergency stop contactor from electrical system or other fault
signals without any fault output or RESET. After stop, operation shall only be available after operation signal re-input,
and inverter shall restart from 0Hz.
Counter trigger signal input (d31):
It shall not be used together with Parameter 0-04, 3-01 and 3-02 and if all set to 0, counting shall not vary.
Description of action: This function terminal TRG can use external triggering signals (e.g. signals near switch,
photoelectric inductors) to make inverter count. And control application based on counting shall be completed by
reference signal of multifunctional output terminals (counting agreement, random counting agreement). Examples
are coiling machine and packing machine.
4-09
Speed tracking after external alarm reset
Factory setting
d 0
Setting range
d 0
Tracking downwards from speed before external alarm
d 1
Tracking upwards from min speed
This function can set the starting mode of inverter after external alarm is reset. The action sequence is same as
sequence after the transient power failure. For detailed action description, see Parameter 8-04~8-07 and diagrams.
4-10 to 4-22
Reserved