486
P009 Speed Ramp 1: Acceleration Time
P009
Range
0
÷
32700
0
÷
327.00 s if
P014
=0
→
0.01 s
0
÷
3270.0 s if
P014
=1
→
0.1 s
0
÷
32700 s if
P014
=2
→
1 s
0
÷
327000 s if
P014
=3
→
10 s
Default
Level
BASIC
Address
609
Function
Determines the time the reference takes to go from 0 rpm to the max. preset
speed (considering the max. value between absolute values for max. speed and
min. speed set for the selected motor).
If S ramps are used, the actual time the reference takes to reach constant rpm
exceeds the time set in
P009
for a percentage equal to (
P022
+
P023
)/2.
P010 Speed Ramp 1: Deceleration Time
P010
Range
0
÷
32700
0
÷
327.00 s if
P014
=0
→
0.01 s
0
÷
3270.0 s if
P014
=0
→
0.1 s
0
÷
32700 s if
P014
=0
→
1 s
0
÷
327000 s if
P014
=0
→
10 s
Default
Level
BASIC
Address
610
Function
Determines the time the reference takes to go from the max. preset speed
(considering the max. value between absolute values for max. speed and min.
speed set for the selected motor) to zero rpm.
If S ramps are used, the actual time the reference takes to reach 0 speed
exceeds the time set in
P010
for a percentage equal to (
P024
+
P025
)/2.
P012 Speed Ramp 2: Acceleration Time
P012
Range
0
÷
32700
0
÷
327.00 s if
P014
=0
→
0.01 s
0
÷
3270.0 s if
P014
=0
→
0.1 s
0
÷
32700 s if
P014
=0
→
1 s
0
÷
327000 s if
P014
=0
→
10 s
Default
Level
ADVANCED
Address
612
Function
Same as ramp 1 (see
P009
).
NOTE
Values for ramp 2 can be applied to the reference provided that multiramp digital inputs
are set up and that ramp 2 is selected (see the DIGITAL INPUTS MENU).