PROGRAMMING GUIDE
SINUS PENTA
123
/
486
P073 Value of ECH Producing Min. Reference (X-axis)
P073
Range
–32000
÷
32000
±
32000 rpm
Default
0
0 rpm
Level
ADVANCED
Address
673
Function
This parameter selects the value of the
Encoder input
for minimum reference, or
better the reference set in
C028xP073a
(Master mode) or in
C047xP073a
(Slave
mode). If motor 2 is active, the values set in
C071
and
C090
will be used instead of
C028
and
C047
; if motor 3 is active, the values set in
C114
and
C133
will be used.
P073a Percentage of Speed_Min/Trq_Min Producing Min. Reference (Y-axis related to P073)
P073a
Range
0
÷
1000
100.0%
Default
1000
100.0%
Level
ADVANCED
Address
702
Function
This parameter represents the max. speed percentage (or the min. torque percentage
for a torque reference) to be used for the maximum reference set with
P073.
P074 Value of ECH Producing Max. Reference (X-axis)
P074
Range
–32000
÷
32000
±
32000 rpm
Default
+1500
+1500 rpm
Level
ADVANCED
Address
674
Function
This parameter selects the value of the
Encoder input
for maximum reference, or
better the reference set in
C029xP074a
(Master mode) or in
C048xP074a
(Slave
mode). If motor 2 is active,
C072
and
C091
will be used instead of
C029
and
C048
; if
motor 3 is active, the values set in
C115
and
C134
will be used.
P074a Percentage of Speed_Max/Trq_Max Producing Max. Reference (Y-axis related to P074)
P074a
Range
0
÷
1000
100.0%
Default
1000
100.0%
Level
ADVANCED
Address
703
Function
This parameter represents the max. speed percentage (or the max. torque
percentage for a torque reference) to be used for the maximum reference set with
P074.