PROGRAMMING GUIDE
SINUS PENTA
87
/
486
P264a Circular Navigation
P264a
Range
0
÷
1
0: [NO]
1: [YES]
Default
1
1: [YES]
Level
ADVANCED
Address
865
Function
Parameter
P264a
is factory set to
1:[YES]. This means that “wrap” navigation is
activated: navigation starts from the first page of the selected menu. Press
▲
to go
to the next page. When the last page is displayed, press
▲
again to return to the
first page of the selected menu.
From the first page of the selected menu, press
▼
to go to the last page of the
active menu.
If
P264a
=0: [NO], when the last page of the active menu is displayed, the
▲
key is
disabled; you can only view the previous pages—up to the first page of the active
menu—by pressing the
▼
key.
P264b Navigation Mode with the MENU Key
P264b
Range
0
÷
1
0: [STANDARD]
1: [OPERATOR]
Default
0
0: [STANDARD]
Level
ADVANCED
Address
512
Function
Press the
MENU
key from any parameter to go to the access page of the menu
containing that parameter; press the
MENU
key again to go to the Root page; press
the MENU key again to go to the Keypad page.
If factory setting is active (
P264b
=0: [STANDARD]) press the
MENU
key from the
Keypad page to go to the Root page, then to the starting parameter. If
P264b
=1:
[OPERATOR], navigation is locked once the Keypad Page is displayed. Hold down
the
ESC
key for
a few seconds to resume navigation. This prevents inexpert users
from navigating through the parameters stored to the keypad. If the Keypad page is
preset as the startup page (
P265
=1: [Measures]) and
P264b
=1 :[OPERATOR],
navigation is always locked.
P265 Startup Page
P265
Range
0
÷
3
0: [Root]
1: [Measures]
2: [Keypad]
3: [Start-Up]
Default
3
3: [Start-Up]
Level
ADVANCED
Address
866
Function
P265
sets the page to be displayed when the drive is turned on.
P265
= 0: the Root page is the startup page.
P265
= 1: the Keypad Page displaying 4 measures only is the startup page.
P265
= 2: The Keypad page displaying a reference in line 4 is the startup page.
P265
= 3: the START-UP MENU is the startup page.