PROGRAMMING GUIDE
SINUS PENTA
241
/
486
P362 MPL2: Testing Variable A
P362
Range
0
÷
7
0: >
1:
≥
2: <
3: ≤
4: ABS(x) >
5: ABS(x) ≥
6: ABS(x) <
7: ABS(x) ≤
Default
0
0: >
Level
ADVANCED
Address
362
Function
This parameter defines the test to be performed for the variable detected by
P360
using
P364
as a comparing value
.
P363 MPL2: Testing Variable B
P363
Range
0
÷
7
0: >
1: ≥
2: <
3: ≤
4: ABS(x) >
5: ABS(x) ≥
6: ABS(x) <
7: ABS(x) ≤
Default
0
0: >
Level
ADVANCED
Address
963
Function
This parameter defines the test to be performed for the variable detected by
P361
using
P365
as a comparing value.
P364 MPL2: Comparing Value for Test A
P364
Range
–32000
÷
32000
–320.00 %
÷
320.00 %
% of the full-scale value of selected variable A,
Default
0
0
Level
ADVANCED
Address
964
Function
This parameter defines the comparing value with the selected variable for test A.
P365 MPL2: Comparing Value for Test B
P365
Range
–32000
÷
32000
–320.00 %
÷
320.00 %
% of the full-scale value of selected variable B
, see Table
Default
0
0
Level
ADVANCED
Address
965
Function
This parameter defines the comparing value with the selected variable for test B.