
PROGRAMMING GUIDE
SINUS PENTA
211/486
P291 MDO3: Testing Variable A
P291
Range
0
÷
7
0: >
1:
≥
2: <
3:
≤
4: ABS(x) >
5: ABS(x)
≥
6: ABS(x) <
7: ABS(x)
≤
Default
0
0: >
Level
ADVANCED
Address
891
Function
This parameter defines the test to be performed for the variable detected by
P289
using
P293
as a comparing value
.
P292 MDO3: Testing Variable B
P292
Range
0
÷
7
0: >
1:
≥
2: <
3:
≤
4: ABS(x) >
5: ABS(x)
≥
6: ABS(x) <
7: ABS(x)
≤
Default
0
0: >
Level
ADVANCED
Address
892
Function
This parameter defines the test to be performed for the variable detected by
P290
using
P294
as a comparing value.
P293 MDO3: Comparing Value for Test A
P293
Range
–32000
÷
32000
–320.00 %
÷
320.00 %
% of the full-scale value of selected variable A,
Default
0
0
Level
ADVANCED
Address
893
Function
This parameter defines the comparing value with the variable selected for test A.
P294 MDO3: Comparing Value for Test B
P294
Range
–32000
÷
32000
–320.00 %
÷
320.00 %
% of the full-scale value of selected variable B
, see Table 48
Default
0
0
Level
ADVANCED
Address
894
Function
This parameter defines the comparing value with the variable selected for test B.
Содержание PENTA MARINE
Страница 173: ...PROGRAMMING GUIDE SINUS PENTA 173 486 Figure 27 Response to the step based on the value of Kp when Ti is kept constant...
Страница 196: ...SINUS PENTA PROGRAMMING GUIDE 196 486 Figure 34 ANALOG Mode Figure 35 DOUBLE DIGITAL Mode...
Страница 197: ...PROGRAMMING GUIDE SINUS PENTA 197 486 Figure 36 General structure of the parameterization of a digital output...