PROGRAMMING GUIDE
SINUS PENTA
57
/
486
M020a PID2 Feedback (%)
M020a
Range
±
10000
±
100.00 %
Note: The actual range depends on the max. value and the min. value
of the PID2 feedback set in parameters
P447-P448
.
Active
This measure is active if enabled from
C291a
Address
1733
Function
This is the measure percent of the PID2 feedback selected with
C286
for the PID2 or the 2-
zone mode. Scaling is detailed in the PID2 PARAMETERS MENU and the PID
CONFIGURATION MENU.
M021 PID Error (%)
M021
Range
±
10000
±
100.00 %
Note: The actual range depends on the min. and max. saturation values of
the reference and the feedback set in parameters
P245
–
P246
for the
reference and in
P247
–
P248
for the feedback.
Active
Always active.
Address
1671
Function
This is the measure of the PID input error expressed as a percentage.
See also the PID PARAMETERS MENU and the PID CONFIGURATION MENU.
M021a PID2 Error (%)
M021a
Range
±
10000
±
100.00 %
Note: The actual range depends on the min. and max. saturation values
of the reference and the feedback set in parameters
P445-P446
for the
reference and in
P447
–
P448
for the feedback.
Active
This measure is active if enabled from
C291a
Address
1736
Function
This is the measure percent of the PID2 input error or the 2-zone mode input error (difference
between the reference selected with
C286
and the feedback selected with
C289
). Please refer
to the PID2 PARAMETERS MENU and the PID CONFIGURATION MENU.
M022 PID Output (%)
M022
Range
±
10000
±
100.00 %
Note: The actual range depends on the min. and max. saturation values of
the PID output set in parameters
P236
–
P237
.
Active
Always active.
Address
1672
Function
This is the measure of the output produced by the PID regulator and expressed as a
percentage. Please refer to the PID PARAMETERS MENU and the PID CONFIGURATION
MENU for the scaling of the PID output
.
M022a PID2 Output (%)
M022a
Range
±
10000
±
100.00 %
Note: The actual range depends on the min. and max. saturation
values of the PID output set in parameters
P436
–
P437
.
Active
This measure is active if enabled from
C291a
Address
1718
Function
This is the measure of the output produced by the PID2 regulator and expressed as a
percentage. Scaling is detailed in the PID2 PARAMETERS MENU and the PID
CONFIGURATION MENU.