PROGRAMMING GUIDE
SINUS PENTA
251
/
486
Parameter
P396
is the X-axis of the
first point;
parameter
P397
is the X-axis of the
second point.
(see also Scaling Analog Inputs REF, AIN1, AIN2).
31.2.
List of parameters P390 to P399
Table 67: List of parameters P390 to P399
Parameter
FUNCTION
User Level
DEFAULT
VALUE
MODBUS
Address
P390
Type of signal over
XAIN4
input
ADVANCED
1:0
÷
10V
990
P391
Value of
XAIN4
input producing min. reference (X-
axis)
ADVANCED
0.0V
991
P391a
Percentage of Speed_Min/Trq_Min producing min.
reference (Y-axis related to
P391
)
ADVANCED
100.0%
704
P392
Value of
XAIN4
input producing max. reference (X-
axis)
ADVANCED
10.0V
992
P392a
Percentage of Speed_Max/Trq_Max producing max.
reference (Y-axis related to
P392
)
ADVANCED
100.0%
710
P393
Offset over
XAIN4
input
ADVANCED
0V
993
P394
Filtering time over
XAIN4
input
ADVANCED
100ms
994
P395
Type of signal over
XAIN5
input
ADVANCED
3: 4
÷
20mA
995
P396
Value of
XAIN5
input producing min. reference (X-
axis)
ADVANCED
4.0mA
996
P396a
Percentage of Speed_Min/Trq_Min producing min.
reference (Y-axis related to
P396
)
ADVANCED
100.0%
711
P397
Value of
XAIN5
input producing max. reference (X-
axis)
ADVANCED
20.0mA
997
P397a
Percentage of Speed_Min/Trq_Min producing min.
reference (Y-axis related to
P397
)
ADVANCED
100.0%
712
P398
Offset over
XAIN5
input
ADVANCED
0mA
998
P399
Filtering time over
XAIN5
input
ADVANCED
100 ms
999
P390 Type of Signal over XAIN4 Input
P390
Range
0
÷
1
0:
±
10 V
1: 0
÷
10 V
Default
1
1:0
÷
10V
Level
ADVANCED
Address
990
Function
This parameter selects the type of single–ended, analog signal over XAIN4
terminal in the terminal board. The signal can be a voltage signal, a unipolar
signal, or a bipolar signal.
0:
±
10 V
Bipolar voltage input between –10V and +10V. The detected signal is
saturated between these two values.
1
: 0
÷
10 V Unipolar voltage input between 0V and +10V. The detected signal is
saturated between these two values.
Содержание PENTA MARINE
Страница 173: ...PROGRAMMING GUIDE SINUS PENTA 173 486 Figure 27 Response to the step based on the value of Kp when Ti is kept constant...
Страница 196: ...SINUS PENTA PROGRAMMING GUIDE 196 486 Figure 34 ANALOG Mode Figure 35 DOUBLE DIGITAL Mode...
Страница 197: ...PROGRAMMING GUIDE SINUS PENTA 197 486 Figure 36 General structure of the parameterization of a digital output...