SINUS PENTA
PROGRAMMING GUIDE
214/486
P300 MDO4: Testing Variable A
P300
Range
0
÷
7
0: >
1:
≥
2: <
3:
≤
4: ABS(x) >
5: ABS(x)
≥
6: ABS(x) <
7: ABS(x)
≤
Default
0
0: >
Level
ADVANCED
Address
900
Function
This parameter defines the test to be performed for the variable detected by
P298
using
P302
as a comparing value
.
P301 MDO4: Testing Variable B
P301
Range
0
÷
7
0: >
1:
≥
2: <
3:
≤
4: ABS(x) >
5: ABS(x)
≥
6: ABS(x) <
7: ABS(x)
≤
Default
0
0: >
Level
ADVANCED
Address
901
Function
This parameter defines the test to be performed for the variable detected by
P299
using
P303
as a comparing value.
P302 MDO4: Comparing Value for Test A
P302
Range
–32000
÷
32000
–320.00 %
÷
320.00 %
% of the full-scale value of selected variable A
, see Table 48
Default
0
0
Level
ADVANCED
Address
902
Function
This parameter defines the comparing value with the selected variable for test A.
P303 MDO4: Comparing Value for Test B
P303
Range
–32000
÷
32000
–320.00 %
÷
320.00 %
% of the full-scale value of selected variable B
, see Table 48
Default
0
0
Level
ADVANCED
Address
903
Function
This parameter defines the comparing value with the selected variable for test B.