SINUS PENTA
PROGRAMMING GUIDE
78
/
486
9. PRODUCT
MENU
9.1. Overview
The Product Menu includes parameter
P263
Language
, allowing the user to select a dialog language; it also contains
the Fire Mode enabling Password and the following information (read-only) about the product:
Product Name and Type
Implemented Software
SW Versions
Serial Number
Manufacturer
9.2. List of Parameter P263 and Fire Mode Enable Passw ord
Table 14: List of parameter P263 and Fire Mode Enable Password
Parameter
FUNCTION
User
Level
DEFAULT VALUE
MODBUS
Address
P263
Language
BASIC
1:ENGLISH
863
Fire Mode Enable Password
BASIC
0
868
P263 Language
P263
Range
0
÷
4
0: ITALIANO
1: ENGLISH
2: ESPAÑOL
3: PORTUGUES
4: DEUTSCH
(F1 version –
standard)
0: DANISH
1: ENGLISH
2: NORWEGIAN
3: FINNISH
4: SWEDISH
(F2 version –
on demand)
0: RUSSIAN
1: ENGLISH
2: ESPAÑOL
3: PORTUGUES
4: DEUTSCH
(F3 version –
on demand)
0: ITALIANO
1: ENGLISH
2: ESPAÑOL
3: PORTUGUES
4: FRANÇAIS
(F4 version –
on demand)
Default
1
1: ENGLISH
Level
BASIC
Address
863
Function
The dialog language is factory set to English. Use parameter
P263
to choose a
different language.
The software implemented in the display/keypad is called MMI (man/machine
interface); its version is displayed in the SW screen of the Product Menu.
CAUTION
The available language set is that of standard version F1.
Versions F2, F3 and F4 are to be explicitly requested at the time when ordering the
drive.
Содержание PENTA MARINE
Страница 173: ...PROGRAMMING GUIDE SINUS PENTA 173 486 Figure 27 Response to the step based on the value of Kp when Ti is kept constant...
Страница 196: ...SINUS PENTA PROGRAMMING GUIDE 196 486 Figure 34 ANALOG Mode Figure 35 DOUBLE DIGITAL Mode...
Страница 197: ...PROGRAMMING GUIDE SINUS PENTA 197 486 Figure 36 General structure of the parameterization of a digital output...