PROGRAMMING GUIDE
SINUS PENTA
439
/
486
53. EXPANSION
BOARD
CONFIGURATION
MENU
53.1. Overview
NOTE
Parameters in this menu are
Rxxx
parameters.
Once saved, they are active only when the drive is next switched on or when the control
board is reset (by holding down the
RESET
key for more than 5 secs).
53.2. List of Parameters R021 to R023
Table 130: List of parameters R021 to R023
Parameter
FUNCTION
User Level
MODBUS Address
DEFAULT
VALUES
R021
Data Logger setting
ENGINEERING
551
Disable
R023
I/O board setting
ENGINEERING
553
None
R021 Data Logger Setting
R021
Range
1
÷
2
1: Disable
2: Enable
Default
1
1: Disable
Level
ENGINEERING
Address
551
Function
This parameter enables or disables Data Logger initialization (if the Data
Logger board is fitted).
R023 I/O Board Setting
R023
Range
0
÷
4
0: None
1: XMDI/O
2: XMDI/O + XAIN
3: XMDI/O + PT100
4: XMDI/O + XAIN + PT100
Default
0
0: None
Level
ENGINEERING
Address
553
Function
Based on the settings in the relevant parameter, this parameter enables
controlling digital I/O (XMDI/O), analog inputs (XAIN) and PT100 probes
located on optional control boards.
NOTE
ES847 is required to control analog inputs (XAIN) and PT100 probes.
Either ES847 or ES870 can be used to control digital I/O (XMDI/O).