SINUS PENTA
PROGRAMMING GUIDE
442
/
486
R045 DRIVE PROFILE SELECTION
R045
Range
0 ÷ 2
0: PROFIDRIVE
1: VENDOR SPECIFIC 1
2: VENDOR SPECIFIC 2
Default
1
1: VENDOR SPECIFIC 1
Level
ENGINEERING
Address
507
Function
This parameter sets the control mode (Command and Reference) for the Slave
station.
0: PROFIDRIVE
1: VENDOR SPECIFIC 1
2: VENDOR SPECIFIC 2
Command
Reference
PROFIDRIVE
According to the PROFIdrive
protocol.
According to the
PROFIdrive protocol.
VENDOR
SPECIFIC 1
According to the PROFIdrive
protocol.
One-to-one scale of the
programmed reference.
VENDOR
SPECIFIC 2
The eight low bits in the CONTROL
WORD represent the eight digital
inputs in the control board.
One-to-one scale of the
programmed reference.
NOTE
Bit 11 in the control board enables or not the Fieldbus line watchdog in any of the three
control modes above, provided that parameter
R016
is set higher than zero.
NOTE
The watchdog activates only after the drive has received the first legal message sent
from the master (see Alarm A070 (Communication Suspended), thus preventing alarm
A070
from tripping due to different power-on times between the master station and the
Penta drive.
Содержание PENTA MARINE
Страница 173: ...PROGRAMMING GUIDE SINUS PENTA 173 486 Figure 27 Response to the step based on the value of Kp when Ti is kept constant...
Страница 196: ...SINUS PENTA PROGRAMMING GUIDE 196 486 Figure 34 ANALOG Mode Figure 35 DOUBLE DIGITAL Mode...
Страница 197: ...PROGRAMMING GUIDE SINUS PENTA 197 486 Figure 36 General structure of the parameterization of a digital output...