27
4 Input Function Parameters
Set during running available
Parameter
Parameter functions
Setting range
Factory setting
4-09
Speed tracking after b.b reset
0:Tracking downwards from speed before b.b
0
1:Tracking upwards from min speed
4-10~4.22
Reserved
Notes:
When 4-04 is set as 1~2, function set by MI2 is invalid. When 4-04 is set as 3
~
4, function set by MI2 and MI3 is invalid.
5 Multi-step Speed and Auto-Program Operation Parameters
Set during running available
Parameter
Parameter functions
Setting range
Factory setting
5-00
1
st
Step Speed
0.0~400Hz
0.0
5-01
2
nd
Step Speed
0.0~400Hz
0.0
5-02
3
rd
Step Speed
0.0~400Hz
0.0
5-03
4
th
Step Speed
0.0~400Hz
0.0
5-04
5
th
Step Speed
0.0~400Hz
0.0
5-05
6
th
Step Speed
0.0~400Hz
0.0
5-06
7
th
Step Speed
0.0~400Hz
0.0
5-07
Reserved
5-08
Reserved
5-09
Reserved
5-10
Reserved
5-11
Reserved
5-12
Reserved
5-13
Reserved
5-14
Reserved
5-15
Auto program Operation Mode
0. Auto operation mode cancelled
0
1. Stop after auto operating for 1 cycle.
2. Auto operation perform in cycles
3. Stop after auto operating for 1 cycle (STOP
intervals).
4. Stop after auto operating for 1 cycle (STOP
intervals).
5~16
PLC Rotating Direction 1 (0 to 7
th
step speed)
0-255( 0: Forward Run 1: Reverse Run)
0
5-17
Reserved
5-18
PLC
Step 0 Time
0~65500S
0
5-19
PLC 1
st
Step Time
0~65500S
0
5-20
PLC 2
nd
Step Time
0~65500S
0
5-21
PLC 3
rd
Step Time
0~65500S
0
5-22
PLC 4
th
Step Time
0~65500S
0
5-23
PLC 5
th
Step Time
0~65500S
0
5-24
PLC 6
th
Step Time
0~65500S
0
5-25
Reserved
5-26
Reserved
Remarks: From 5-18 to 5-33, the time premium is set more than 9999, and the “.” under the unit nixietube means
multiplying current value by 10. For example, d1000. means the setting value is 10000.