31
A: Wobble Frequency Function Parameters Set during running available
Parameter
Parameter functions
Setting range
Factory setting
A-00
Wobble Frequency selection
0:Not applying
0
1:Applying
A-01
Wobble Frequency input mode
0:Input automatically
0
1:Manually controlled by externa l
terminals.
A-02
Pre-set frequency of Wobble
Frequency
0.0~400Hz
0.0
A-03
Action delay setting of preset
Wobble Frequency
0.0~600(s)
0.0
A-04
Central frequency option of Wobble
Frequency
0:According to operation frequency source
0
1:According to fixed frequency setting
A-05
Fixed central frequency setting(Max
frequency ) of Wobble Frequency
0.01~100% Fmax
20.0
A-06
Reference source setting for wobble
aptitude
0:Relative centering frequency
0
1:Relative Max frequency
A-07
wobble aptitude size setting
0.0~50.0%
0.00
A-08
wobble frequency hopping (Relative
aptitude )
0.0~50.0%
0.00
A-09
wobble frequency circle
0.1~655(s)
10.0
A-10
Triangle wave rising time(Relative
cycle)
0.1~99.9%
50.0
A-11
wobble frequency machine stop
starting mode
0:Starting in memorizing state before
machine stop
0
1:Restarting
A-12
wobble state power loss memory
0:Memorizing
0
1:Non-memorizing