32
5 DESCRIPTION OF FUNCTIONAL PARAMETERS
All the functional parameters are described in detail in this chapter. According to attributes, the
parameters can be divided into 11 groups; in most of the applications, presetting for operation
shall be completed by performing with these parameters of groups.
The 11 groups of parameters are listed as below:
0: User’s Parameters
1: Basic Parameters
2: Operation Mode Parameters
3: Output Function Parameters
4: Input Function Parameters
5: Multi-step and Auto-program Operation Parameters
6: Protection Parameters
7: Motor Parameters
8: High Function Parameters
9: Communication Parameters
A : Wobble Frequency Function Parameters
*
: indicates that for 440V class, value shall be 2 times of setting.
: indicates that it’s available to be set during running.
0 User’s Parameters
0-00
Machine type code recognition of AC motor drive (Only for reading)
Factory setting d#
Setting range
Non
AC motor drive machine type code shall be read through this parameter, and for capacity of the
drive, which has been set at factory, please see diagram below. Also, it shall be applied to judge
whether current in parameter (0-01) corresponds with rated current of the specific machine.
Parameter 0-00 corresponds with 0-01 as the diagram below indicates.
220V(type code)
d1
d2
d3
d4
d5
Power KW
0.2
0.4
0.75
1.5
2.2
Horsepower HP
0.25
0.5
1
2
3
rated current 0-01(A)
1.6
2.5
4.2
7.5
11.0
440V(type code)
d10
d11
d12
d13
d14
Power KW
0.4
0.75
1.5
2.2
3.7
Horsepower HP
0.5
1
2
3
5
rated current 0-01(A)
1.5
2.5
4.2
5.5
8.2