42
多功能输出接点指示:
multi-function output junction indication
指定计数值到达
specified counting value reach
设定计数值到达
set counting value reach
3-03
Fwd run reference delay setting
Factory setting
d 0.0
Setting range
d 0.0<->d 60.0S
Unit
0.1S
3-04
Rev run reference delay setting
Factory setting
d 0.0
Setting range
d 0.0<-> d 60.0S
Unit
0.0S
When 3-05 is set as 17,18 and 19, above two parameters match with it to use.
3-05
Multifunctional output contactor reference
Normally Open Contactor(RA-RC)
Normally Closed Contactor(RB-RC)
Factory setting
d 8
Setting range
d 0<->d 19
Unit
1
Function List
Set value Description of function
d 0
No function
d 1
Reference during running. If output occurs to motor drive, output terminal contactor which sets this parameter
shall be CLOSED.
d 2
Set frequency agreement reference. When output frequency of motor drive agrees with set frequency, this
contactor shall be CLOSED.
d 3
Reference during zero speed. When motor drive set frequency is less than Min starting frequency setting, this
contactor shall be CLOSED.
d 4
Over-torque detection reference. This contactor shall be CLOSED when over-torque is detected by motor
drive.
d 5
Reference during BB. This contactor shall be CLOSED when b.b happens to motor drive.
d 6
Low voltage detection reference. This contactor shall be CLOSED when input voltage over-low is detected
by motor drive.
d 7
Motor drive operation mode reference. This contactor shall be CLOSED when AC motor drive reference is
controlled by external terminals.
d 8
Fault reference. This contactor shall be CLOSED when fault is detected by AC motor drive
d 9
Random frequency agreement reference. This contactor shall be CLOSED when output frequency agrees
with appointed reference (3-00).
d 10
Reference during program auto-running. This contactor shall be CLOSED when program auto-running
performed.
d 11
Reference of step running completion. During program auto-running, this contactor shall be CLOSED after
each running step, but it shall maintain only for 0.5sec.
d 12
Reference of program running completion. This contactor shall be CLOSED after completion of program
running, but it shall maintain only for 0.5sec.
d 13
Program running pause. This contactor shall be CLOSED when external pause auto-running is in action
during program auto running.
d 14
Set count agreement. This contactor shall be CLOSED when count value is equivalent with set value of
Parameter 3-01.
d 15
Appointed count agreement. This contactor shall be CLOSED when count value is equivalent with set value of
Parameter 3-02.
Display Value
External count triggering signal
(Output Signal)
Multifunction output terminal
Appointed count agreement
Set count agreement
Width of triggering signal