FORMat:BORDer
<ByteOrder>
Controls whether binary data is transferred in normal or swapped byte order.
Parameters:
<ByteOrder>
NORMal | SWAPped
SWAPped - the least significant byte is transferred first (little
endian).
NORMal - the most significant byte is transferred first (big
endian).
*RST:
SWAPped (if the GPIB Language is set to PNA or
HP xxxx, then the order is NORMal)
Example:
FORM:BORD NORM
Change the byte order to normal mode.
Manual operation:
See
7.3.8 HCOPy Commands
The
HCOPy...
commands control the output of screen information to an external
device. Part of the functionality of this system is included in the "File" menu.
.............................................................................................904
..........................................................................................905
.......................................................................................... 905
........................................................................................... 905
.................................................................................... 906
......................................................................................... 906
........................................................................................ 906
...........................................................................................907
............................................................................................. 907
HCOPy[:IMMediate]
Initializes the print according to the current
HCOPy...
configuration.
Example:
HCOP:DEST '<Printer_name>'
Select the printer for the output of screen data.
HCOP
Start printing.
Usage:
Event
Manual operation:
See
SCPI Command Reference