131
INSTALLATION
INSTALLATION
2.11.5
Electrical data of the high head pump motors
No.
(**)
Description
(***)
NXC - NXH
044
048
056
064
072
084
096
104
122
142
164
Motors of single and dual high-pressure pumps (option 116R, 116S, 116V, 116W)
1
Nominal efficiency at full load
and nominal voltage
84,8
84,8
84,8
84,8
84,8
84,8
84,8
84,8
85,9
85,9
85,9
%
1
Nominal efficiency at 75% rated
load and nominal voltage
82,2
82,2
82,2
82,2
82,2
82,2
82,2
82,2
84
84
84
%
1
Nominal efficiency at 50% rated
load and nominal voltage
79
79
79
79
79
79
79
79
82,1
82,1
82,1
%
2
Efficiency level
IE3
-
3
Year of manufacture
This information varies depending on the manufacturer and model at the time
of incorporation. Please refer to the motor name plates.
-
4
Manufacturer's name and tra-
demark, commercial registration
number and place of manufac-
turer
-
5
Product's model number
-
6
Number of motor pole
2
2
2
2
2
2
2
2
2
2
2
-
7-1
Rated shaft power output at full
load and nominal voltage (400V)
1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7
2,2
2,2
2,2
kW
7-2
Maximum power input (400V)
(****)
2,4
2,4
2,4
2,4
2,4
2,4
2,4
2,4
2,9
2,9
2,9
kW
8
Rated input frequency
50
50
50
50
50
50
50
50
50
50
50
Hz
9-1
Rated voltage
3 x 400
V
9-2
Maximum current drawn (400V)
(†)
4,2
4,2
4,2
4,2
4,2
4,2
4,2
4,2
5
5
5
A
10
Rated speed
2870
2870
2870
2870
2870
2870
2870
2870
2855
2855
2855
rpm
48
r/s
(1)
11
Product disassembly, recycling or
disposal at end of life
Disassembly using standard tools.
Disposal and recycling using an appropriate company.
-
Operating conditions for which the motor is specifically designed
12
I - Altitudes above sea level
< 1000
(††)
m
II - Ambient air temperature
< 55
°C
IV - Maximum air temperature
Please refer to the operating conditions given in this manual.
°C
V - Potentially explosive atmo-
spheres
Non-ATEX environment
-
(1)
Revolution per second
(*)
Required by the regulation 640/2009 with regard to the application of directive 2009/125/EC on the eco-design requirements for
the electric motors.
(**) Item number imposed by regulation 640/2009, annex I2b.
(***) Description given by regulation 640/2009, annex I2b.
(****) To obtain the maximum power input for a unit with hydronic module add the maximum unit power input from the electrical data
table to the pump power input.
(†) To obtain the maximum unit operating current draw for a unit with hydronic module add the maximum unit current draw from
the electrical data table to the pump current draw.
(††) Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.
Содержание 20120391
Страница 93: ...93 PANORAMICA DEI PARAMETRI INSTALLAZIONE ...
Страница 169: ...169 ALARM CODES INSTALLATION ...
Страница 185: ...185 OVERVIEW OF THE PARAMETERS INSTALLATION ...
Страница 186: ......
Страница 187: ......