Operating Manual 1176.7578.02 ─ 09
Setting parameters:
<MeasOnlyOnBurst> MEAS | BURS
*RST:
MEAS
Example:
DDEM:SEAR:BURS:MODE BURS
Measurement is performed only if burst is found.
Mode:
VSA
Manual operation:
See
"Meas only if burst was found"
[SENSe:]DDEMod:SEARch:BURSt:SKIP:FALLing
<RunOut>
This command defines the length of the falling burst edge which is not considered
when evaluating the result.
The default unit is symbols. The value can also be given in seconds.
Setting parameters:
<RunOut>
numeric value
Range:
0 to 15000
*RST:
1
Default unit: SYM
Example:
DDEM:SEAR:BURS:SKIP:FALL 5US
5
µ
s of the rising burst edge are not considered
Mode:
VSA
[SENSe:]DDEMod:SEARch:BURSt:SKIP:RISing
<RunIn>
This command defines the length of the rising burst edge which is not considered when
evaluating the result. The default unit is symbols. The value can also be given in sec-
onds.
Setting parameters:
<RunIn>
numeric value
Range:
0 to 15000
*RST:
1
Default unit: SYM
Example:
DDEM:SEAR:BURS:SKIP:RIS 5US
5 us of the rising burst edge are not considered
Mode:
VSA
[SENSe:]DDEMod:SEARch:BURSt:STATe
<SearchState>
This command switches the search for a signal burst on or off.
Setting parameters:
<SearchState>
ON | OFF
*RST:
OFF
SENSe subsystem
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...