Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
264
Operating Manual 1176.7578.02 ─ 09
is turned off, this command has no immediate
effect on the screen.
Suffix:
<n>
.
window; For applications that do not have more than 1 measure-
ment window, the suffix <n> is irrelevant.
<t>
irrelevant
Parameters:
<Mode>
ABSolute
absolute scaling of the y-axis
RELative
relative scaling of the y-axis
*RST:
ABS
Example:
DISP:TRAC:Y:MODE REL
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe][:PDIVision]
<Range>
This remote command determines the grid spacing on the Y axis for all diagrams,
where possible
Suffix:
<n>
.
1..4
<t>
1..6
irrelevant
Setting parameters:
<Range>
numeric value
Range:
1 to 1000000
*RST:
100
Default unit: NONE
Example:
DISP:TRAC1:Y:PDIV 2 dB
Mode:
VSA
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RLEVel
<ReferenceLevel>
This command defines the reference level.
With the reference level offset
≠
0, the value range of the reference level is modified by
the offset.
Suffix:
<n>
.
irrelevant.
<t>
irrelevant
DISPlay subsystem