Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
299
Operating Manual 1176.7578.02 ─ 09
[SENSe:]DDEMod:QAM:NSTate
<QAMNState>
This command defines the demodulation order for QAM.
NSTate
Order
16
16QAM
16
Pi/4-16QAM
32
32QAM
32
Pi/4-32QAM
64
64QAM
128
128QAM
256
256QAM
Setting parameters:
<QAMNState>
numeric value
*RST:
16
Example:
DDEM:FORM QAM
Switches QAM demodulation on.
DDEM:QAM:NST 64
Switches 64QAM demodulation on.
Mode:
VSA
[SENSe:]DDEMod:QPSK:FORMat
<Name>
This command defines the demodulation order for QPSK.
FORMat
Order
NORMal
QPSK
DIFFerential
DQPSK
OFFSet
OQPSK
DPI4
PI/4 DQPSK
Setting parameters:
<Name>
NORMal | DIFFerential | DPI4 | OFFSet
*RST:
NORMal
Example:
DDEM:FORM QPSK
Switches QPSK demodulation on.
DDEM:QPSK:FORM DPI4
Switches pi/4 DQPSK demodulation on.
Mode:
VSA
Manual operation:
See
SENSe subsystem