Support
R&S
®
FSV-K70
343
Operating Manual 1176.7578.02 ─ 09
Figure 6-7: GSM EDGE burst; Pattern is actually located in the middle of the burst. The correct
value for "Offset" here would be 58.
Solution: Try one of the following:
–
Remove the offset ('unknown').
–
Enter the correct offset (within about 4 symbols of tolerance).
For more information, see
–
●
The specified pattern does not coincide with the pattern in your signal:
In the R&S FS
Q
-K70 it is possible to search for multiple patterns at the same time.
For example, in a GSM measurement, the capture buffer can be checked for all
TSCs simultaneously. This is not possible in the R&S
FSV-K70.
Solution:
Make sure that the correct pattern is specified in the "Signal Description" dialog.
For more information, see
–
Message: Sync failed. Check for all zero signal.
A prerequisite for correct synchronization is a random data sequence of an adaquate
size.
Solution: Make sure the input signal contains an adaquate number of uncorrelated
(random!) bits. (Not
0 0 0 0 0
,
1 1 1 1 1
, or
01 01 01 01 01
, for example.)
For QAM modulation, the result length (the data on which synchronization is based)
should correspond to at least 8 times the modulation order (see
Message: Result Alignment Failed
The result range alignment is not possible for the patricular capture buffer. The result
range needs I/Q data that has not been captured.
Explanation of Error Messages
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...