Signal is bursted, but bursts have not been captured completely
The burst search can only find bursts that start and end within the capture buffer. It
ignores bursts that are cut off.
Figure 6-2: Example for incomplete burst capture
Solution: Change the trigger settings and/or enlarge the capture length.
For more information, see
–
●
The current measurement is being performed on a burst that has not been
captured completely.
Figure 6-3: Example for measurement on incomplete burst capture
Figure 6-4: Example for measurement on complete burst capture
Solution:
Change the trigger settings or increase the result length.
Note, however, that in this case, the results are actually correct and the message
can be ignored.